EasyManua.ls Logo

Motorola AT Commands G24-L - CCLK Parameters

Motorola AT Commands G24-L
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Phone Books and Clock
3-74 G24-L AT Commands Reference Manual April 15, 2008
The following table shows the +CCLK parameters.
Example
AT+CCLK=?
+CCLK: "88/12/31, 23:59:59, (-47-+48)"
OK
AT+CCLK="01/01/01, 01:01:01-08"
OK
AT+CCLK?
+CCLK: "01/01/01, 01:01:01-08"
OK
AT+CCLK="02/02/02, 02:02:02"
OK
Power cycling…
AT+CCLK?
+CCLK: "02/02/02, 02:02:02+00"
OK
AT+CCLK="03/03/03, 03:03:03+50"
+CME ERROR: Numeric parameter out of bounds
AT+CCLK
OK
AT+CCLK?
+CCLK: "05/10/27,16:52:31+08"
Power cycling…
AT+CCLK?
+CCLK: "05/10/27,16:52:50+08"
OK
Table 3-40: +CCLK Parameters
<Parameter> Description
<time> ASCII string of format:
yy/MM/dd,hh:mm:ss±zz
or
yy/MM/dd,hh:mm:ss
yy - 2-digit year [2000-2069]
MM - 2-digit month [01-12]
dd - 2-digit day of month [00-31]
hh - 2-digit hour [00-23]
mm - 2-digit minute [00-59]
ss - 2-digit seconds [00-59]
zz - (optional) time zone offset from GMT, in quarter-hours [-47...+48]. If this value is
not specified, the time zone offset will be 0.