EasyManuals Logo

Motorola AT Commands G24-L User Manual

Motorola AT Commands G24-L
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #217 background imageLoading...
Page #217 background image
Chapter 3: AT Commands Reference
April 15, 2008 G24-L AT Commands Reference Manual 3-153
+MMAD:1,160
//Operation not allowed because the parameters are valid but the
there is not enough time for calculation:
AT+MMAD =1,3,100, , ,7,1,5 // Activate Average calcluation during 1 minute, rate=100,
// samples = 7, report interval = 5 sec.
//converter num=1, report=3, rate=100, low,high, 7,
// duration=1 min, interval = 5.
+CME ERROR: operation not allowed
AT+MMAD =1,0 // Stop Average calcluation and report.
OK // converter num=1, report=0
AT+MMAD? // Read monitoring setup values of all A2D's
+MMAD:1,0,10,0,230,0,0,0
+MMAD:2,1,15,0,230,0,0,0
+MMAD:3,2,1,25,100,0,0,0
+MMAD:5,0,1,300,450,0,0,0
OK
AT+MMAD? // Read default values of all A2D's
+MMAD: 1,0,1,0,230,0,0,0
+MMAD: 2,0,1,0,230,0,0,0
+MMAD: 3,0,1,0,230,0,0,0
+MMAD: 5,0,1,300,450,0,0,0
OK
AT+MMAD=? //Test command - range of all setup parameters and
+MMAD: (1-3,5),(0-3),(1-255),(0-450),(0-450),(2-255),(1-255),(0-255)
OK
+MPCMC, Continuous PCM Clock
This command defines whether the PCM clock is generated continuously or not, when module is
in digital audio mode (configured by AT+MADIGITAL command).
Note: User is advised not to enable sleep mode feature if he wants to use continuous PCM clock
feature. Otherwise PCM clock will not work correctly while module is in deep sleep
mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola AT Commands G24-L and is the answer not in the manual?

Motorola AT Commands G24-L Specifications

General IconGeneral
BrandMotorola
ModelAT Commands G24-L
CategoryNetwork Hardware
LanguageEnglish

Related product manuals