Model 493.02 Controller Service
Hydraulic Configurations
228
Independent HSM with HPU (FO-LO)
Note This interconnect option is only available for controllers on the same
interlock.
For this controller configuration:
• Two or more FlexTest SE controllers are connected.
• An HSM is connected to each controller only.
• Select Auto. HPU/HSM for Power Type on the controller to which
both a HSM and HPU is connected.
Path: Config > Edit Hardware > Power Options > Power Type
> Auto. HPU/HSM
• Select HSM Only for Power Type on controllers with an
independent HSM, but no HPU.
Note The HPU can be connected to any controller in the interconnected
group of controllers.
FlexTest SE
Emergency Stop
7
8 9
65
4
3
2
1
.
0
+/-
enter
cancel
FG
Setup
Status
Scope
Meters
Tunin g
Config
Limits
Log
Menu
?
A
B
Recall
Enabled
reset
Rewind Run
Hold
Stop
Power
Program
Hydraulic
Interlock
Program
Interlock
HPU
HSM
Off
Low
High
Off
Low
High
Navigate
Monitor 1
Monitor 2
FlexTest SE
Emergency Stop
7
8 9
65
4
3
2
1
.
0
+/-
enter
cancel
FG
Setup
Status
Scope
Meters
Tunin g
Config
Limits
Log
Menu
?
A
B
Recall
Enabled
reset
Rewind Run
Hold
Stop
Power
Program
Hydraulic
Interlock
Program
Interlock
HPU
HSM
Off
Low
High
Off
Low
High
Navigate
Monitor 1
Monitor 2
Power Type = HSM Only
Interlock/Hydraulics
HPU
HSM 1
561264-xx
J28 HSM
J25 HPU
397137-xx
563160-xx
Power Type = Auto. HPU/HSM
HSM 2