Model 493.02 Controller Service
Model 493.42 System I/O Connections
Cabling
62
J29 Emergency Stop Connections
Connector J29 E-STOP provides an output to external devices when
an emergency stop signal is generated. This connector may also be
used with an external E-stop.
.
J29 Connector Pin Assignments
P
IN NAME FUNCTION
1 Xhead 24V Fused +24V
2 Xhead intlk com 24V common
3 Program interlock low (xhead
interlock low)
Low side of opto-isolator, jumpered to common
4 Program interlock high
(xhead interlock high)
High side of opto-coupler, pulled up to 24V (opto on = intlk)
5 Local E stop Local E stop loop (connected to pin 7)
6 N/C No connection
7 Local E stop Local E stop loop (connected to pin 5)
8 HPU E stop E stop loop from HPU (connect to pin 13)
9 N/C No connection
10 N/C No connection
11 N/C No connection
12 Xhead power +24V crosshead unlock power output (from HSM high relay
contact)
13 HPU E stop E stop loop from HPU (connect to pin 8)
14 xhead power return 24V common for crosshead unlock power output
15 N/C

Table of Contents

Other manuals for MTS Systems FlexTest SE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest SE and is the answer not in the manual?

MTS Systems FlexTest SE Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest SE
CategoryController
LanguageEnglish

Related product manuals