Model 493.02 Controller Service
Installing the Plug-in Modules
Installation
28
VMEbus Modules
S
LOT MODULE NAME FUNCTION
Slot 1 PowerPC® Provides PIDF processing for the Controller and management
of the other plug-in modules in the stand-alone configuration.
Provides an interface between the Controller and an external
computer in the automated configuration.
Slot 2 Model 493. 40 I/O Carrier Supports up to four daughter boards that can be used for
sensor conditioning, driving a servovalve, and in the
automated configuration, providing A/D and/or D/A channels.
Slot 3 Blank in standard
configurations.
May be used for additional
Model 493.40 I/O Carrier
(factory installed option for
PC-supervised systems)
Addition carrier chassis that can house up to four daughter
boards for expanded sensor conditioning and A/D and D/A
channels
Note This is not a stnadard option. It is available only for
PC-supervised systems and must be configured at
the factory. For more information, contact MTS.
Slots 4, 5 Model 493.42 System I/O Provides box-in and box-out connections for daisy chaining
multiple Controllers, analog and digital I/O, E-Stop, and HSM
and HPU control.
Model 493.40 I/O Carrier Daughter Boards (part 1 of 2)
M
ODEL MODULE NAME FUNCTION
493.14 Valve Driver Produces the control signal for a Series 252 Servovalve.
493.15 3–Stage Valve Driver Produces the control signal for a Series 256 or 257
Servovalve.
493.25 Universal Conditioner Processes the signals from either an AC or DC-type sensors.
493.45 A/D Converts up to six external analog signals to digital signals for
use by the controller.
493.46 D/A Converts up to six internal digital signals to analog signals for
use by external devices.