EasyManuals Logo

MTS Systems FlexTest SE Service Information

Default Icon
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Model 493.02 Controller Service
Model 493.42 System I/O Connections
Cabling
68
J54 Digital Inputs
Connector J54 Dig In accommodates up to three digital signals from
external devices. You can use digital input signals to trigger test events
with your controller applications.
All of the inputs are optically isolated.
Channel inputs can be 3 volts (minimum) and 26 volts (maximum)
from an external voltage source.
.
Cable specification The cabling information shown assumes a single cable destination
(with an overall shield). In other applications, the cable may have
more than one destination. For these applications an overall shield is
not practical and non-EMI connectors and back shells are permissible.
9 pin contact type D male EMI connector
Back shell–EMI metallized plastic
Cable–shielded twisted pairs as required (24 AWG minimum) with
drain wire(s) connected to the metallized backshell at the chassis.
J54 Connector Pin Assignments
P
IN NAME FUNCTION
1 dig in 24V 24 V through 6.6K resistor
2 dig in 1 high High side of opto-isolator (opto on = logic 1)
3 dig in 1 low Low side of opto-isolator
4 dig in 2 high High side of opto-isolator (opto on = logic 1)
5 dig in 2 low Low side of opto-isolator
6 dig in 3 high High side of opto-isolator (opto on = logic 1)
7 dig in 3 low Low side of opto-isolator
8 dig in com 24V common
9 dig in com 24V common

Table of Contents

Other manuals for MTS Systems FlexTest SE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest SE and is the answer not in the manual?

MTS Systems FlexTest SE Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest SE
CategoryController
LanguageEnglish

Related product manuals