Transducer Connections
Model 493.02 Controller Service
Sensors
85
Temposonics III
connections
A Temposonics III transducer requires a DC conditioning daughter
board.
Force/strain sensor
connections
Force and strain sensors require a DC conditioning daughter board.
TO
493.40 CARRIER MODULE
(TEMPOSONICS III
DAUGHTER BOARD)
Data
Clock
+
+
-
-
+24 V
COM
TO
493.74
AUX POWER
Data
Clock
+24 V
COM
+
-
+
-
FROM
TEMPOSONICS III
SENSOR
C
B
D
A
GND
DC Sensor
Inner
Guard
4
2
1
3
5
-FB
+FB
-EX
+EX

Table of Contents