Technical Manual N5 (CANopen)
10 Description of the object dictionary
4014h Operating Conditions
Function
This object is used to read out the current environment values for the controller.
Object description
Index 4014
h
Object name Operating Conditions
Object Code ARRAY
Data type INTEGER32
Savable no
Access read only
PDO mapping no
Allowed values
Preset value
Firmware version FIR-v1540
Change history
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 01 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 02 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Name" entry changed from
"Temperature PCB [d?C]" to "Temperature PCB [Celsius * 10]".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 03 changed from "read/write" to "read only".
Value description
Subindex 00
h
Name Highest Sub-index Supported
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 03
h
Subindex 01
h
Name Voltage UB Power [mV]
Data type INTEGER32
Access read only
PDO mapping TX-PDO
Allowed values
Preset value 00000000
h
Subindex 02
h
Version: 2.0.1 / FIR-v1650 293