Chapter 13: Wedge to USB MSR Software Migration 13-3
OnyourcurrentWedgeMSRyouaremostlikelyusingeitherthe
defaultOPOSWedgeprofile(NCRMSR.1)oraprofilewithanameof
yourchoice,whichisconfiguredthesameasthedefaultprofile.Ifyou
wanttokeepthesameprofilenameyoumustreplacetheexisting
Wedge
configuredprofilewithaprofilebythesamenameconfigured
tousetheUSBMSR.BelowisthedefaultNCRMSR.3profileshowing
theproperconfigurationoptionsforusingtheUSBMSR.
[HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ServiceOPOS\MSR\NCR
MSR.3]
@="NCRFitClient.MSR"
"Description"="NCR 74XX MSR Service Object"
"MSR"="USB"
"NCRVersion"="2.4.1.0 -> NCR Release File Version"
"ProductID"="0 -> ProductID: Maximum 0xFFFF hex"
"TimeOut"="800"
"Type"="ISO"
"VendorID"="0 -> VendorID: Maximum 0xFFFF hex"
"Version"="1.3.0"
NorticethedefaultvaluefortheProgrammaticIDis
NCRFitClient.MSRandthattheMSRtypeisUSB.TheVendorIDand
ProductIDare0soanyUSBMSRthatisdetectedwillbeused.
IMPORTANT NOTE:
TheNCRFitClient.MSRprofilethroughFitClientLEorRSMLEhas
anoptionforTone.ThismustbeDisabled(settoFalse)forUSBMSR.If
itissettoEnabled(True)theMSRwillnotwork.