Default Settings
Enabled
System Availability
Terminals
Standard SIP Phone
Multiline and Single Line Terminals
Required Component(s)
None
Related Features
None
Guide to Feature Programming
Program
No.
Program Name Input Data Default
11-12-08 Service Code Setup (for Service Access) -
Barge-In
0~9,
*
, # Maximum of 8 digit 710
11-12-47 Service Code Setup (for Service Access) - SLT
Call Waiting Answer/Split Answer
0~9,
*
, # Maximum of 8 digit 794
11-12-57 Service Code Setup (for Service Access) - Unsu-
pervised Conference/Tandem Trunking
0~9,
*
, # Maximum of 8 digit #8
11-12-58 Service Code Setup (for Service Access) - Trans-
fer Into Conference
0~9,
*
, # Maximum of 8 digit 624
11-16-02 1-digit Service Code Setup - Barge-In 0~9,
*
, # Maximum of 1 digit No Setting
14-01-04 Basic Trunk Data Setup - Transmit Gain Level for
Conference and Transfer Calls
1 ~ 63
(- 15.5 dB ~ + 15.5 dB in 0.5 dB
intervals)
32 (0 dB)
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
20-06-01 Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15 Extension 101 is Class
15 and other Extension
are Class 1
20-11-21 Class of Service Options (Hold/Transfer Service)
- Restriction for Tandem Trunking on Hang Up
0 = Allow
1 = Deny
COS 01 ~ 15 = 0
20-13-08 Class of Service Options (Supplementary Serv-
ice) - Conference
0 = Off
1 = On
COS 01 ~ 15 = 1
20-13-10 Class of Service Options (Supplementary Serv-
ice) - Barge-In Monitor
0 = Speech
1 = Monitor
COS 01 ~ 15 = 0
ISSUE 1.0 SL2100
Features and Specifications Manual 1-207