Program
No.
Program Name Input Data Default
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
16-02-01 Department Group Assignment for Extensions Department Groups 1 - 50
Priority 1 - 200
Refer to Programming
Manual.
20-06-01 Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15 Extension 101 is Class
15 and other Extension
are Class 1
20-11-09 Class of Service Options (Hold/Transfer Service)
- Group Hold Initiate
0 = Off
1 = On
COS 01 ~ 15 = 1
20-11-10 Class of Service Options (Hold/Transfer Service)
- Group Hold Answer
0 = Off
1 = On
COS 01 ~ 15 = 1
20-11-13 Class of Service Options (Hold/Transfer Service)
- Operator Transfer After Hold Callback
0 = Off
1 = On
COS 01 ~ 15 = 1
20-17-01 Operator Extension - Operator’s Extension Num-
ber
Up to eight digits 101
24-01-01 System Options for Hold - Hold Recall Time 0 ~ 64800 seconds 90
24-01-02 System Options for Hold - Hold Recall Callback
Time
0 ~ 64800 seconds 0
24-01-03 System Options for Hold - Exclusive Hold Recall
Time
0 ~ 64800 seconds 90
24-01-04 System Options for Hold - Exclusive Hold Recall
Callback Time
0 ~ 64800 seconds 0
24-01-05 System Options for Hold - Forced Release of
Held Call
0 ~ 64800 seconds 1800
Operation
System Hold
To place an outside call on System Hold:
Press Hold key.
To pick up an outside call on System Hold:
1. If you know the specific line number, dial 672 + Line number (001 ~ 128).
Exclusive Hold
To place an outside call on Exclusive Hold:
Press the Exclusive Hold key (PRG 15-07-01 or SC 751: 45).
Single Line Terminal
1. Hookflash.
2. Dial 749.
SL2100
ISSUE 1.0
1-344
Hold