Email forwarding requires one (1) InMail Email Notification License (1014) for the system. .
Constant Message Count is displayed on a telephone display until another activity needs the display
(i.e., if a call is made or received on the telephone). To have the message count display again, the
telephone needs to receive a new voice mail message or a new call into the voice mailbox.
The Quick Transfer to Voice Mail feature is allowed when:
- Listening to the Ring Back Tone (RBT).
- Listening to the Call Waiting Tone (CWT).
- In Handsfree Answerback Mode.
- In Voice Over Mode.
When Quick Transfer to Voice Mail is accessed, the Voice Over feature is canceled.
While on an intercom (ICM) call, dial the Quick Transfer Access Code (default: 8) to automatically
transfer to that station Voice Mail box.
The Quick Transfer to Voice Mail is not allowed when caller is:
- Listening to the busy tone (BT).
- Talking on an internal line.
- Talking on an outside line.
- Making a conference call.
Extension numbers cannot start with 0, 9,
or #.
Distribution List members can only have 2 or 3 digit extension IDs.
Live Record does not work for monitored calls.
Live Record does not work for conference calls.
Fixed Call Forwarding can be used to transfer a user’s unanswered calls to their voice mail. Call
Forwarding does not have to be programmed manually by each user.
Caller ID information is passed from the Voice Mail to an extension for pre-answer display on an
unscreened transfer from Voice Mail.
Off-premise notification and external extensions require access to outside lines.
When the voice mail places a call on hold, it uses Group Hold. Any line appearances for the trunk
shows the hold flash rate, however, a user cannot pick up this call (a busy signal is heard).
Updating the system time also updates the InMail time.
The displayed message count for New and Saved messages does not update until the mailbox user
hangs up and calls back into the InMail.
InMail and Analog Voice Mail cannot be used at the same time in the same system.
The number of speech path channels on the CPU for the In Mail and the VRS feature are shared
and depends if the EXIFB-C1 board is installed.
- Without an EXIFB-C1 board installed the systems supports a maximum of four channels for VRS
and/or InMail.
- With an EXIFB-C1 board installed, the system supports a maximum of 16 channels for VRS
and/or InMail. The maximum number of channels supported for InMail is eight.
When installing a SDVMS/SDVML card onto the CPU-C1 the system MUST be powered off. Never
install or uninstall the SDVMS/SDVML card while the system is under power.
Default Settings
Disabled
System Availability
Terminals
All Terminals
SL2100
ISSUE 1.0
1-406
InMail
I