Type 2 (Range of Days) Example
Answer Table 1 Answer Schedule 1
Answer Schedule 1 is a Range of
Days schedule that starts schedule
that runs Sunday through Wednes-
day from 8:30 AM to 5:00 PM.
47-12-01 : Entry01 Schedule Type = 2
47-12-02 : Entry01 MB Ctg = 3
47-12-02 : Entry01 MB Num = 1
47-12-03 : Entry01 Day = 1 (Entry does not matter)
47-12-04 : Entry01 Start Day = 1 (Sunday)
47-12-05 : Entry01 End Day = 4 (Wednesday)
47-12-06 : Entry01 Date (MMDD) = 0000 (Entry does not
matter)
47-12-07 : Entry01 Start Time = 0830 (8:30 AM)
47-12-08 : Entry01 End Time = 1700 (5:00 PM)
Answer Schedule 2
Answer Schedule 2 is a Range of
Days schedule that runs Thursday
and Friday from 11:00 AM to 1:00
PM.
47-12-01 : Entry01 Schedule Type = 2
47-12-02 : Entry01 MB Ctg = 3
47-12-02 : Entry01 MB Num = 2
47-12-03 : Entry01 Day = 1 (Entry does not matter)
47-12-04 : Entry01 Start Day = 4 (Wednesday)
47-12-05 : Entry01 End Day = 5 (Thursday)
47-12-06 : Entry01 Date (MMDD) = 0000 (Entry does not
matter)
47-12-07 : Entry01 Start Time = 1100 (11:00 AM)
47-12-08 : Entry01 End Time = 1300 (1:00 PM)
Type 3 (Date) Answer Schedule Options
Type 3 (Date) Example
In this example, Answer Table 1 routes calls as follows:
Schedule 1 uses Routing Mailbox 1 and runs every day from 8:30 AM to 5:00 PM.
Schedule 2 uses Routing Mailbox 9 and runs only on Christmas day from 8:30 AM to 5:00 PM.
At all other times, routing is handled by the Default Mailbox specified in PRG 47-11-03 : Default
Mailbox Category and PRG 47-11-03 : Default Mailbox Number.
When setting up Answer Tables with multiple types, build the Answer Schedules in the following order:
Range of Days
Day of Week
Date
ISSUE 1.0 SL2100
Features and Specifications Manual 1-423