Program
No.
Program Name Input Data Default
16-02-02 Department Group Priority Assignment 1 ~ 999 (Refer to the program-
ming manual for the
default values of all ex-
tensions.)
45-01-01 Voice Mail Integration Options - Voice Mail De-
partment Group Number
0 = No Voice Mail Assigned
1 ~ 50 = Department Group 1 ~
50
0
45-01-07 * Voice Mail Integration Options - Centralized
Voice mail Pilot No.
Maximum of 8 digits (0 ~ 9,
, #,) No Setting
45-01-08 * Voice Mail Integration Options - Centralized
Voice Mail Department Group Number
0 ~ 50
0 = No Voice Mail Assigned
0
45-01-09 * Voice Mail Integration Options - Centralized
Voice Mail master Name
Up to 12 characters C.V.M.
45-01-10 * Voice Mail Integration Options - New NSL Proto-
col support
0 = Off (Disable)
1 = On (Enable)
0
84-34-01 * VoIPDB DTMF Setup - DTMF Relay Mode 0 = Disable
1 = RFC 2833
2 = H.245
0
84-38-10 * VoIPDB Network Side Echo Canceller Setup - Tx
Level Control
0 = Disable
1 = Manual
2 = Auto
3 = HLC
(for SIP Trunk Profile 1 - 6)
0
84-38-13 * VoIPDB Network Side Echo Canceller Setup - Tx
HLC Threshold
0 ~ 42 (- 42 dBm ~ 0 dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
(for SIP Trunk Profile 1 - 6)
41
84-38-14 * VoIPDB Network Side Echo Canceller Setup - Tx
Signal Limiter mode
0 = Disable
1 = Enable
(for SIP Trunk Profile 1 - 6)
0
84-38-15 * VoIPDB Network Side Echo Canceller Setup - Tx
Signal Limiter Threshold
0 ~ 42 (- 42 dBm ~ 0 dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
(for SIP Trunk Profile 1 - 6)
41
90-10-01 System Alarm Setup - Alarm Type 0 = Not Set
1 = Major Alarm
2 = Minor Alarm
-
90-10-02 System Alarm Setup - Report 0 = Not Report (No autodial)
1 = Report (autodial)
Refer to the Program-
ming Manual for the
default values.
AspireNet Basic Features
Refer to the SL2100 Feature and Specifications Manual for a complete description and programming
information for the following features. The information detailed here applies only to the feature when
used in a Networked system.
ICM calling
An extension user can make an intercom call to a networked system if the networked extensions are
defined with the Network Access Code (PRG 11-01, Dial Type = 8). A user can change the signaling
ISSUE 1.0
SL2100
Features and Specifications Manual 1-53
A