Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Station Selection (DSS) Console
Paging, External
Programmable Function Keys
Ring Groups
Ecology
Guide to Feature Programming
The programs listed below indicate the most commonly used programs required for this feature. The
programs are listed in the order that the installer should follow. Refer to the PCPro wizards for further
detailed programming.
• When a * is listed next to the Program Number it indicates a program that MUST be set (from a
default state) for this feature to be enabled.
Manual Night Mode
Program
No.
Program Name Input Data Default
12-01-01 Night Mode Function Setup - Manual Night Mode
Switching
0 = Off (Manual Night Mode
changes are not allowed.)
1 = On (Manual Night Mode
changes are allowed.)
1
12-05-01 Night Mode Group Assignment for Extensions -
Night Mode Service Group Number
1 = Night Mode Group 1
2 = Night Mode Group 2
3 = Night Mode Group 3
4 = Night Mode Group 4
1
12-06-01 Night Mode Group Assignment for Trunks -
Night Mode Service Group Number
1 = Night Mode Group 1
2 = Night Mode Group 2
3 = Night Mode Group 3
4 = Night Mode Group 4
1
12-07-01 Text Data for Night Mode - Text Message Maximum 12 Characters (alpha-
betic or numeric)
Mode 1 = No Setting
Mode 2 = <Night>
Mode 3 = <Mid-night>
Mode 4 = <Rest>
Mode 5 = <Day2>
Mode 6 = <Night2>
Mode 7 = <Midnight2>
Mode 8 = <Rest2>
12-08-01 Night Mode Service Range - Range 2 ~ 8 2
12-08-02 Night Mode Service Range - Lamp setting of tog-
gle key
0 = Off
1 = On
0
20-01-17 System Options - Day/Night Change Key Mode 0 = Toggle (Will follow PRG
12-08-01.)
1 = Skip (When pressed the sys-
tem will step to the next night
mode time period in PRG 12-02.)
0
ISSUE 1.0 SL2100
Features and Specifications Manual 1-663