Guide to Feature Programming
Program
No.
Program Name Input Data Default
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
20-06-01 Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15 Extension 101 is Class
15 and other Extension
are Class 1
20-07-10 Class of Service Options (Administrator Level) -
Programmable Function Key Programming (Ap-
pearance Level)
0 = Off
1 = On
COS 1 ~ 15 = 1
20-13-18 Class of Service Options (Supplementary Serv-
ice) - Programmable Function Key Programming
(General Level)
0 = Off
1 = On
COS 01 ~ 15 = 1
20-13-49 Class of Service Options (Supplementary Serv-
ice) - BLF Indication on CO Incoming State
0 = Off (Disabled)
1 = On (Enabled)
COS 01 ~ 15 = 0
Operation
To change a 2-digit programmable key:
1. Press Speaker key.
2. Dial 751 for 2-digit codes.
3. Press the key you want to program.
4. Enter the 2-digit key function, any additional information needed for the key and press Hold key.
For available functions codes refer to PRG 15-07 in the SL2100 Programing Manual.
To undefine a key, enter 00.
To change a 3-digit programmable key:
1. Press Speaker key.
2. Dial 752 for 3-digit codes.
3. Press the key you want to program.
4. Enter the 3-digit key function and any additional information needed for the key.
For available functions codes, refer to PRG 15-07 in the SL2100 Programing Manual.
To undefine a key, enter 000.
When a key is programmed using service code 752, that key cannot be programmed with a function
using the 751 code until the key is undefined (000). For example with a Park Key programmed by
dialing 752 +
04 must be undefined by dialing 000 before it can be programmed as a Voice Over key
by dialing 751 + 48.
To check the function of a programmable key:
1. Press Help key.
ISSUE 1.0
SL2100
Features and Specifications Manual 1-713
P