Room Monitor is for listening only. It does not allow for conversation between the monitoring and
monitored extensions.
An extension user cannot monitor an Attendant.
A Multiline Terminal user cannot monitor a Single Line Terminal and a Single Line Terminal cannot
monitor a Multiline Terminals.
Room Monitor for Single Line Terminals can be used with the Hotel/Motel feature.
For a Multiline Terminal, Room Monitor requires uniquely programmed function keys.
Call Arrival (CAR) Key (virtual extension) keys do not support Room Monitor Programmable
Function keys (code 39).
Default Settings
Disabled
System Availability
Terminals
Multiline Terminals and Single Line Terminals
Required Component(s)
None
Related Features
Hotel/Motel
Programmable Function Keys
Guide to Feature Programming
Program
No.
Program Name Input Data Default
11-14-17 Service Code Setup (for Hotel) - Hotel Room
Monitor
0~9,
*
, # Maximum of 8 digit 675
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
20-06-01 Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15 Extension 101 is Class
15 and other Extension
are Class 1
20-13-11 Class of Service Options (Supplementary Serv-
ice) - Room Monitor, Initiating Extension
0 = Off
1 = On
COS 01 ~ 15 = 0
20-13-12 Class of Service Options (Supplementary Serv-
ice) - Room Monitor, Extension Being Monitored
0 = Off
1 = On
COS 01 ~ 15 = 0