SNMP traps can be used for the purpose of monitoring SL2100 alarms via SNMP. When an alarm is
triggered on the SL2100, they can be reported in the SNMP application.
Supported traps are as follows:
ColdStart trap
LinkDown trap
LinkUp trap
Authentication Failure trap
Conditions
An SNMP browser is required to manage and view SNMP traps.
When properly configured, an SL2100 sends trap to SNMP Application.
A properly configured MIB OID file which is fully compiled in the MIB browser is required before the
MIB browser can perform Get operations from the SNMP agent.
The "Target Host" parameter referenced in Program 90-64 is the SNMP network management
device (s) that are run on an external PC.
SL2100 do not support warmStart trap, epgNeighborLoss trap and enterpriseSpecific trap.
Default Settings
None
System Availability
Terminals
None