please,” and quickly extends the call to the desired party. This ensures that all incoming calls are
answered quickly
, courteously and consistently.
Conditions
VRS record time is fixed at four minutes per message and cannot be changed.
The Automated Attendant (VRS) can answer up to 16 calls (Needs EXIFB) simultaneously.
The maximum number of VRS ports is 16 when the EXIFB is installed on the CPU. If the EXIFB is
not installed, the maximum number of VRS ports is four.
Default Settings
Disabled
System Availability
Terminals
None
Required Component(s)
None
Related Features
Transfer
Guide to Feature Programming
Program
No.
Program Name Input Data Default
11-10-20 Service Code Setup (for System Administrator) -
VRS - Record/Erase Message
0~9,
*
, # Maximum of 8 digit 616
11-10-21 Service Code Setup (for System Administrator) -
VRS - General Message Playback
0~9,
*
, # Maximum of 8 digit 611
11-10-22 Service Code Setup (for System Administrator) -
VRS - Record or Erase General Message
0~9,
*
, # Maximum of 8 digit 612
11-12-54 Service Code Setup (for Service Access) - VRS
Routing for ANI/DNIS
0~9,
*
, # Maximum of 8 digit 782
15-07-01 Programmable Function Keys - Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
20-06-01 Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15 Extension 101 is Class
15 and other Extension
are Class 1
20-07-13 Class of Service Options (Administrator Level) -
VRS Record (VRS Msg Operation)
0 = Off
1 = On
COS1 ~ 14/COS15 =
0/1