TECHNICALCHARACTERISTICSOFTHEPRODUCT
WARNINGS: • All technical specications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modica-
tions to products at any time when deemed necessary, maintaining the same intended use and functionality.
TechnicalcharacteristicsSLH400
Type Electromechanical gear motor for the automatic movement of sliding gates for residential use,
complete with electronic control unit
Pinion Z: 15; Module: 4; Step: 12.6 mm; Primitive diameter: 60mm
Peakthrust[correspondingtotheabilityto
developaforcecapableofmovingtheleaf]
12Nm; corresponding to the capacity to move a leaf with a dynamic friction of up to 400N
Nominaltorque[correspondingtotheabil-
itytodevelopaforcecapableofmaintain-
ingthemovementoftheleaf]
6Nm; corresponding to the capacity to move a leaf with a dynamic friction of up to 200N
Nominaltorquespeed 0.18m/s
Idling speed (the control unit allows 6
speedstobeprogrammed,approx.equal
to:100,85,70,55,45,30%)
0.34m/s
Maximumfrequencyofoperating cycles
(nominaltorque)
35 cycles / day (the control unit allows up to the maximum described in tables 2 and 3)
Maximumcontinuousoperatingtime(nomi-
naltorque)
10 minutes
Operatinglimits In general, SLIGHT is suitable for the automation of gates featuring weights of up to 400 kg or
lengths of up to 6m as shown in Tables 1 and 2
Durability Estimated between 20.000 cycles and 180.000 cycles, depending on the conditions reported in
Table 3
SLIGHTpowersupply 230Vac (+10% -15%) 50/60Hz.
Thrustmaximumabsorbedpower[equiva-
lenttoamperes]
330W
Insulationclass 1 (a safety grounding system is required)
Emergencypowersupply With PS124 optional accessory
Flashinglightoutput For 2 LUCYB ashing lights (12V, 21 W lamp)
OpenGateIndicatorOutput For one 24V maximum 4W bulb (the output voltage may vary between –30 and +50% and can
also control small relays)
BLUEBUSoutput One output with a maximum load of 15 BlueBus units
STOPinput For normally open contacts, for 8,2KΩ; constant resistance, or normally closed contacts; with
selfrecognition (any variation from the memorized status causes the “STOP” command)
Step-by-stepInput For normally open contacts (the closing of the contact causes the “STEP-BY-STEP” command)
OPENinput For normally open contacts (the closing of the contact causes the “OPEN” command)
CLOSEinput For normally open contacts (the closing of the contact causes the “CLOSE” command)
Radioconnector “SM” connector for SMXI and SMXIS receivers
RadioAERIALInput 52Ω for RG58 or similar type of cable
Programmablefunctions 8 ON-OFF functions and 8 adjustable functions (see tables 7 and 9)
Self-Recognitionfunctions Automatic identication of devices connected with the BlueBus outlet
Self-recognition of the type of “STOP” device (Normally Open, Normally Closed contact or 8,2KΩ)
Self-recognition of the gate length and calculation of the deceleration points and the partial open-
ing point.
Operatingtemperature -20°C ÷ 50°C
Useinacid,salineorpotentiallyexplosive
atmosphere
No
Protectionclass IP 44 on the nished product if installed according to proper installation criteria
Dimensionsandweight 131x135xh405; 6.5 kg