7360 ISAM FX-16 shelf cabling
100
ANSI Hardware Installation Manual
3HH-12893-AAAA-TCZZA Issue: 09
DRAFT
6.2 Safety precautions
The following safety precautions apply:
Danger 1 —  Before working on the power supply unit, verify 
whether it is live.
If the power supply is live, which can deliver −48 Vdc, you must 
use an insulated tool kit. See 7360 ISAM FX Safety Manual for 
more information about working with live components.
Danger 2 —  Avoid risk of electric shock.
Always wear protective gloves and footwear for all handling 
tasks.
Carefully follow the instructions.
Warning 1 —  Before connecting to the power, verify the 
specifications of all equipped fan units to ensure that the 
correct voltage will be supplied (−48 Vdc) to these units.
Warning 2 —  Before power is supplied, all fasteners requiring 
a specific torque must be tightened moderately before final 
tightening with a torque wrench or driver.
When power is supplied, tighten fasteners with insulated tools, 
according to the specified torque.
Warning 3 —  For Type 2 ports:
The intra-building port(s) of the 7360 ISAM FX equipment or 
sub-assembly is suitable for connection to intra-building or 
unexposed wiring or cabling only.
Warning 4 —  For Type 2 ports that require shielded cables:
The intra-building port(s) of the 7360 ISAM FX equipment or 
sub-assembly must use shielded intra-building wiring or 
cabling that is grounded at both ends.