21
5.2.3 Setting the steam bath time
Note: this menu item is available only if the operating mode in the steam bath control settings (see
chapter 5.3.3.1) is set to “Panel” and the control mode is set to “Manual” (see chapter 5.2.2).
Select “Duration” in the main menu, then press the <Set> key.
In the upcoming modication dialogue set the desired steam bath time.
Factory setting: 45 minutes
Setting range: 1 ... 1080 minutes
5.2.4 Conguringthefragrancepump(s)
Select “Fragrance” in the main menu, then press the <Set> key. In the upcoming display, select the
desired fragrance pump whose settings you want to modify, then press the <Set> key.
In the upcoming modication dialogue set the desired intensity level (1-5 or 0: fragrance pump deacti-
vated) for the selected fragrance pump.
Factory setting: 0
Setting range: 0: fragrance pump deactivated
1: interval time: 10 minutes, pulse duration: 2 seconds
2: interval time: 8 minutes, pulse duration: 3 seconds
3: interval time: 6 minutes, pulse duration: 3 seconds
4: interval time: 4 minutes, pulse duration: 4 seconds
5: interval time: 3 minutes, pulse duration: 5 seconds
Note: the fragrance pump is active only, if the main contactor of the steam generator is activated and
the system is in steam bath operation.
Note: the interval time and the pulse duration of the fragrance injection can be set individually in the
engineering level. If necessary, please contact your Nordmann service technician.
Main Menu
Operat.Mode :Manual
Duration :45min
Fragrance :Set
Setpoint :48°C
Light-2 :O
Esc Set
Menu Light Start
AT4D 65kg/h 400V3
Steam Bath :Standby
Temperature :34°C
Setpoint :48°C
2011-08-31 12:00:00
Duration
45 min
45 min
Esc Set
Main Menu
Duration :45min
Fragrance :Set
Light-2 :O
Operat.Mode :Manual
User :Set
Esc Set
Fragrance
Aroma2 Level:0
Fragrance :Set
Aroma1 Level:0
Esc Set
Menu Light Start
AT4D 65kg/h 400V3
Steam Bath :Standby
Temperature :34°C
Setpoint :48°C
2011-08-31 12:00:00
Aroma1 Level
0
0
Esc Set

Table of Contents