EasyManua.ls Logo

Nordmann Engineering AT4 D - Cleaning Unit Components; Cleaning Water Hoses, Inlet Valve, Drain Pump, and Water Cup

Nordmann Engineering AT4 D
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63
6.4 Notes on cleaning the unit components
Unit component What to clean and how to clean
Water hoses
Remove any limescale by slightly knocking on the tubes
using a rubber hammer. Then, rinse the tubes well with
hot tap water.
Inlet valve
strainer insert
Use a brush (do not use a wire brush) to remove any
limescale inside the inlet valve and on the strainer.
Wash inlet valve and strainer insert with a lukewarm
soap solution, then rinse well with tap water.
Let the inlet valve dry before reinstallation!
Drain pump
O-ring
Pump wheel
Use a brush to remove any limescale from the pump
housing and the pump wheel (do not use a wire
brush).
Then, wipe pump wheel with a damp cloth. Wash the
pump housing with a lukewarm soap solution and rinse
well with tap water.
Let the drain pump dry before reinstallation!
Water cup
Remove any limescale from the water cup and its con-
nectors using a brush (do not use a wire brush).
If the water cup is heavily calcied, place it in an 8%
formic acid solution (observe safety notes in chap-
ter 6.5), until the limescale comes off.
Wash the water cup with a lukewarm soap solution and
rinse well with tap water.

Table of Contents

Other manuals for Nordmann Engineering AT4 D

Related product manuals