PROPlus / PRO Series Automated Dispensing Systems
38 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
System Setup Screen
Click the System Setup tab to go to the System Setup screen. This screen includes fields for system settings and
provides access to the Robot Initial Setup wizard and to the Laser Detect Setup wizard. Refer to the sections of the
manual referenced below for detailed information on these fields.
System Setup
Screen Area
Function
Axis Limit Refer to “Setting System Parameters”
on page43.
Speed Refer to “Setting System Parameters”
on page43.
Line Acc
Point to point Acc
Refer to “Setting System Parameters”
on page43.
Offset Alarm Refer to “Setting System Parameters”
on page43.
Language Refer to “Setting System Parameters”
on page43.
IO Refer to “Setting Up Inputs / Outputs”
on page58.
Park Position Refer to “Setting System Parameters”
on page43.
Tip Detect Device Used only as needed for manual
calibration of the tip-to-workpiece
offset in place of using the Robot Initial
Setup wizard. Refer to “AppendixB,
Non-Wizard Setup Procedures” on
page135.
Version Shows the current version of the
software
Auto Purge Refer to “How to Set Up Auto Purge,
Program Cycle Limits, or Fluid Working
Life Limits” on page93.
Run Limit
Fluid Working
Life
Password Refer to “Setting Password Protection”
on page46.
Lock Program
Enable File
Switch
Refer to “How to Lock or Unlock a
Program” on page65.
Pre-cycle
Initialize
Causes the robot to move to the home
position (0, 0, 0) before starting a
dispense cycle.
System Setup
Screen Area
Function
Needle XY Adjust Enables or disables the Needle XY
Adjust capability. When Needle XY
Adjust is checked, the Needle XY
Adjust button appears on the Program
screen.
Tip Detect Device Specifies whether a tip detector
present. When Tip Detect Device is
checked, the Needle Z Detect button
appears on the Program screen.
2D Code Enables or disables the QR code
scanning capability.
Multi Needles Enables or disables the Multi Needle
capability (used if the system includes
more than one dispenser).
Height Sensor Specifies whether the optional
height sensor is installed. This item
is not applicable for PROPlus / PRO
systems.
Set Z to Focus Specifies how the system captures Z
values in command windows.
Model drop-
down menu
Specifies the robot model.
Expert For advanced users only.
Laser Detect
Setup
(Laser systems
only)
Used only as needed for calibration of
the laser-to-tip offset. Refer to “(Laser
Systems Only) Calibrating the Laser
and Setting the Tip-to-Workpiece
Offset” on page56.
Exit Closes the software.
Robot Initial
Setup
Opens the system setup and
calibration wizard. Refer to “Setting Up
and Calibrating the System (Required)”
on page47 for the system setup
procedures.
Light Refer to “Setting System Parameters”
on page43.