EasyManua.ls Logo

NORMALAB NDI 450 User Manual

NORMALAB NDI 450
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
NORMALAB France
2012
N O R M A L A B F r a n c e
1/118
NORMALAB France
MAINTENANCE NOTICE
NDI 450

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NORMALAB NDI 450 and is the answer not in the manual?

NORMALAB NDI 450 Specifications

General IconGeneral
TypeRefractometer
ModelNDI 450
ManufacturerNORMALAB
DisplayLCD
InterfacesRS232
Refractive Index Range1.3000 to 1.7000
Resolution0.0001
Accuracy±0.0002
Temperature ControlYes
Wavelength589 nm
Sample Volume0.3 ml

Summary

2 Structure of the machine

2.1 Mechanical structure

Details the mechanical components and layout of the NDI 450 instrument.

2.2 Environnement of the machine

Specifies installation and environmental requirements for proper operation and longevity.

2.3 Electronic structure

Explains the electronic architecture, boards, and external connections of the NDI 450.

3 Instruction sheets

3.1 Access to parts of the machine

Procedures for opening panels and accessing internal components of the NDI 450.

3.2 Level follower

Maintenance and replacement procedures for the level follower system.

3.3 Heating block

Maintenance and replacement procedures for the heating block.

3.5 Cooling condenser system

Procedures for maintaining the cooling condenser system.

3.7 Chassis

Maintenance tasks related to the instrument chassis.

3.8 Electronic drawer

Procedures for components within the electronic drawer.

3.9 Front panel

Maintenance and replacement of front panel components.

4 Calibration and maintenance functions

4.1 Calibration functions

Overview of calibration options and procedures available for the instrument.

4.3 Calibration of sample temperatures

Detailed procedures for calibrating sample temperature measurements.

4.6 Calibration of the barometric sensor

Steps for calibrating the barometric sensor.

4.7 Calibration of test tubes

Recommended calibration procedures for test tubes.

5 Denomination and functions of the electronic boards

5.1 Process CPU

Role of the Process CPU in managing acquisitions, regulations, and processes.

5.2 MMI CPU

Function of the MMI CPU for managing orders and peripherals.

5.3 CL1 board

Function of the CL1 board in managing sensors.

5.4 CL2 board

Function of the CL2 board as an interconnection board.

5.5 CL3 board

Role of the CL3 board, functioning as a relay board.

6 Schematic electrical and electronic

6.1 Interconnection scheme

Diagram illustrating the interconnection scheme of the instrument's components.

6.2 Spares part list

List of available spare parts for the instrument.

6.3 Scheme of electronic boards

Diagrams showing the schematics of the instrument's electronic boards.

8 Troubles shooting

General troubleshooting

Covers issues like circuit breaker problems, blown fuses, and power supply faults.

Result and measurement issues

Addresses problems with divergent temperatures, incorrect boiling points, and flow rate regulation.

Instrument operation problems

Troubleshooting for level follower errors, detection failures, and final volume inaccuracies.

9 Annexe 1

9.1 Guide to update instrument

Instructions and guidance for updating the NDI 450 instrument.

9.2 Safety rules

Important safety rules to follow when operating the NDI 450.

9.10 Install a new MMI version using the Update option

Procedure for installing a new MMI software version via the update option.

9.11 Install a new firmware version using the Update option

Procedure for installing a new firmware version using the update option.

9.12 Error messages

Information and troubleshooting for common error messages encountered.

10 Annexe 2

10.1 Logbook

Section containing logbook entries and self-diagnostic information.

11 Alarm list