Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
16Copyright©2016NortekSecurity&Control
Solid State Output
TheControlPanelprovidesone(1)solidstateoutputthat
canbeprogrammedtoactivateduringvariousconditions.
Theoutputcanswitchupto250mA@16VDCtoground.
NOTE: ForETLList ing,anexternalDCBackupPowerSupply
isrequiredforaloadconnectedtoTermi nal4.
NOTE: WhentheControlPanelisconnectedwithanAC
powersource,Terminal1providesDCPoweronly.
Figure 8 Solid State Output
ThisoutputonlyfunctionswhiletheControlPanelis
receivingpowerfromthewallpowersupply.
1 Installthedevicetobecontrolledbythesolidstate
output.
2 RoutewiringfromthedevicelocationtotheControl
Panel swallcutout.
WARNING: Toavoiddamagetotheoutput,doNOT
connectanelectromechanicalbelltotheseterminals.
Optional 2GIG Go!Control POTS Module
Tousethetelephonejack,youmustinstallthe2GIG
Go!ControlPOTSModule.Boththeincomingandoutgoing
telephonelinecanbeconnected.
Figure 9 2GIG Go!Control POTS Module
Whenthedigitalcommunicatoractivates,alllocal
telephonesaredisconnectedtopreventanoffhook
telephoneonthepremisesfromblockingthedigital
communicatorscall.
Figure 10 2GIG Go!Control POTS Module Installation