Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
20Copyright©2016NortekSecurity&Control
Control Panel Wiring
Thethird‐handhangingstrapallowsyoutohangthe
ControlPanelonthemountingplateduringinstallation.
1 HangtheControlPanelonthemountingplatebythe
third‐handhangerstrap.
2 Connectthehardwireloop,externalsounder,andopen
collectoroutputwiring(ifused)totheControlPanel’s
terminalblock.
3 Plugthetelephoneline(ifused)intothetelephonejack
onthePOTSModule.
Figure 15 Third-Hand Hanging Strap
Terminal Block Wiring Diagram
Figure 16 Terminal Block Wiring Diagram
Backup Battery Connection and Power
Supply Wiring
ThebackupbatteryconnectstotheControlPanel’ scircuit
boardwithatwo(2)‐pinheaderassembly.
Thepowersupplyfeaturesatwo(2)‐positionterminalblock
forconnectingthepowersupplytotheControlPanelpower
terminals(connectionwirenotincluded).
1 Locateanunswitchedwalloutletfortheplug‐inpower
supply.
WARNING: Neverconnectthepowersupplytoswitch‐
controlledoutlet.
2 Routetwo(2)‐conductorwirefromthepowersupply
locationtotheControlPanelmountingplate.Forwire
sizeandmaximumlength,see
"WireSizeandLength"
onpage20.
3 Beingcarefultoobservepolarity,connectthewireto
thepowersupply’sDC+andDC‐terminals.DoNOTplug
thepowersupplyintoanoutletatthistime.
4 Beingcarefultoobservepolarity,connectthewireto
theControlPanelinputterminals14VDC(+)Te rminal1
and14VDC(‐)Terminal2.
NOTE: GroundingoftheControlPanelisNOTrequiredfor
properoperation.
5 Plugthebackupbatterypack’ sconnectorintothe
connectorontheControlPanel’scircuitboard.The
ControlPaneldoesnotrecognizethatthebatteryis
connecteduntilACpowerisconnectedtothepower
supply.
NOTE: Thestandardbackupbatterythatisincludedwithall
2GIGControlPanelsdoesnotsupportUL985
installations.Tocomplywiththesecondarysupply
requirementinUL985:HouseholdFireWarningSystem
Units,installthe2GIGConsoleBatteryPack(Thisisa
high‐capacity2600mAhNi‐MHreplacementbattery
pack).
Wire Size and Length
Toensureproperoperation,doNOTex ceedthefollowing
maximumlengthforthewiresizeinstalled:
TIP: Toensurethattheappropriatewir esizeandlengthis
installed,measurethevoltagebetweenthepower
connectionterminalsatthebackoftheControlPanel.
Thevoltagemeasuredmustnotfallbelow11volts
DC
ortheControlPanelmaydisplaynuisance“ACPower
Loss”messagesandsendACLossReportstotheCentral
Station.See"Q52:ACLossReportstoCS(0‐1)"onpage
58.
A Third‐handhangingstrap
B Hardwireloops,externalsounder,andopencollectoroutput
connectedtoterminals.
C TelephonejackonthePOTSmodule
1 14VDCPowerInput(+)
2 14VDCPowerInput(‐)
3 Ground
4 OpenCollector
5 Bell(+)
6 Bell(‐)
7 HardwireLoop1
8 HardwireLoop2
WireSize MaximumLength
22AWG 55ft(16.8m)
20AWG 85ft(25.9m)
22AWG2‐pairs
(19AWGequivalent)
110ft(33.5m)
18AWG 135ft(41.1m)