Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
60Copyright©2016NortekSecurity&Control
IftheoptionalGSM(Cellular)RadioModuleisinstalled,the
telephonelinefailurewillstillbereportedifthisquestionis
enabled.
•Thedefaultsetting(0)DisabledturnsthisfeatureOFF.
•Toturnonthi
sfeature,select(1)Enabled.
NOTE: If(0)Disable
disselectedinQ8:Dialer,telephone
linefailuredetectionisalsodisabledregardlessofthe
settingspecifiedhereinQ63:PhoneFailDetect.
Q64: Smart Test Reports
DEFAULT:(0)Disabled
SmarttestreportsareawaytoreduceCentralStation
traf fic.Ifsmarttestreportsareenabledandregular
periodictestreportsareenabled,anynon‐testreporttothe
CentralStation(alarm,restore,trouble,etc.)duringthe
normaloperationofthesystemwillresettheperiodictest
reporttimer
.Periodictestreportswouldonlybesentifthe
ControlPanelhasnotreportedinanywaytotheCentral
Station.
•Thede
faultsetting(0)Disabledpreventssmarttest
reports.
•Toallo
wsmarttestreports,select(1)Enabled.
Q65: RF Jam Causes Trouble (0-1)
DEFAULT:(0)Disabled
ThesystemcanmonitortheControlPanel’ ssensorreceiver
anddetectwhetheratransmitterisstuckontheaircausing
jamming.Whenjamdetectisenabled,theControlPanel
willindicateatroubleconditionifRFjammingisdetected.
NOTE: Thispr
ogrammingquestiononlyfunctionsiftrouble
reportsareenabledwithprogrammingquestionQ50.
•Thede
faultsetting(0)DisabledturnsRFjam
detectionOFF.
•ToturnonRFjamde
tection,select(1)Enabled.
Q66: Daylight Saving (0-1)
DEFAULT:(1)Enabled
TheControlPanelcanadjustitsdisplayedclockandinternal
clockforDa ylightSavingTime(DST).Ifthecellradioisused,
thetimewillbeautomaticallyadjustedregardlessofthis
setting.Thesystemdefaultissettousethecurrentstart
(March)andend(November)datesfortheUn
itedStates.
TheDSTstartandenddatescanbeadjustedasfollows:
•Thede
faultsetting(1)EnabledturnsONtheDST
clockforthesystem.
•Toturnof
ftheDSTclock,select(0)Disabled.
NOTE: Ifena
bled,respondtoprogrammingquestionsQ67,
Q68,Q69,andQ70tomodifythestartandstopvalues
forDST.
Q67: Daylight Saving Start Month (01-12)
DEFAULT:(03)March
•Thede
faultDSTstartmonthissetto(03)March.
•Toch
angethestartmonthforyourcountry,region,
orstate,enterthedesiredmonth,(01‐12)January‐
December:
Q68: Daylight Saving Start Monday (1-7)
DEFAULT:(2)2ndSunday
•Thedefault(2)setsthesecondSundayasthe
daylightsavingstartweek.
•Tochangethest
artweek,enterthe1st,2nd,3rd,
4th,last,secondfromlast,thirdfromlast(1‐7)as
thedaylightsavingstartweek.
Q69: Daylight Saving End Month (01-12)
DEFAULT:(11)November
•Thede
fault(11)Novemberdefinesthedaylight
savingendmonth.
•Tochangetheendmon
thforyourcountry,region,
orstate,enterthedesiredmonth,(01‐12)January‐
December.
Q70: Daylight Saving End Sunday (1-7)
DEFAULT:(1)1stSunday
•Thede
faultsetting(1)1stSundaydefinesthe
daylightsavingendweek.
•Tochangetheendwee
k,enterthe1st,2nd,3rd,
4th,last,secondfromlast,thirdfromlast(1‐7)as
thedaylightsavingendweek.
Q71: System Tamper Causes Trouble (0-
1)
DEFAULT:(1)Enabled
AtamperswitchontheControlPaneldetectsifthecasehas
beenopened.Thesystemcanbeprogrammedsothata
tamperswitchactivationwillcauseatroubleindicationif
thesystemisdisarmed,andanalarmifthesystemis
armed.
•Thede
fault(1)allowstheControlPaneltamper
switchtotriggertroublewhenthesystemis
disarmed,andalarmwhenthesystemisarmed.
•Toha
vethesystemignoretheControlPaneltamper
switch,select(0)Disabled.
Q72: Quick Bypass (0-1)
DEFAULT:(0)Disabled
Normally,sensorsthatareviolated(open)atthetimethe
systemisarmedwillrequiretheusertoentertheircodeto
forcebypassthem.TheControlPanelcanbeprogrammed
sothatwhenthesystemisarmedwithopensensors,a
codeisnotrequiredtobypasstheopense
nsor(s)and
completethearming.
•Thede
faultsetting(0)Disabledrequiresenteringa
codetobypasssensors.
•Toallowbypa
ssingsensorswithoutacode,select
(1)Enabled.
Q73: Disarming Keyfob After Alarm
(Alert) (0-1)
DEFAULT:(0)Disabled
Thesystemcanproduceauniquesoundwhenit’sdisarmed
withakeyfobafteranalarmhasoccurred.Fourbeepswill
soundfromtheControlPanel’sspeaker,fourchirpswill
soundfromtheexternalsounder(ifinstalled).Thisfeature