Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
58Copyright©2016NortekSecurity&Control
Q46: Trouble Doesn’t Sound at Night (0-
1)
DEFAULT:(1)Enabled
NOTE: Fo
rUL985:HouseholdFireWarningSystemUnits
installations,thissettingmustbesetto(0)Disabled
TheCon
trolPanelwillsoundtroublebeepscausedbyAC
loss,systemlowbattery,sensorlowbatteryorRF
supervision,failuretocommunicate,ControlPaneltamper
whiledisarmed,andcellradiofaults.
Topreventannoyingthesubscriber,thesystemcanbeset
tosuppresstroublebeepsfromsoundingfrom10
PMto9
AM.Thetroublealertsarestilldisplayedandimmediately
reportedtotheCentralStation,andcanbeacknowledged,
buttheywon’tsoundbeepsuntilafter9AM.
Ifthetroublecondition(s)self‐clearorareacknowledged
before9AM,notroublebeepssoundafter9AM(the
conditionsarestillrecordedintheeventlog).
•Thede
faultsetting(1)Enabledsuppressestrouble
beepsfrom10
PMto9AM
•Toallowtroublebeepsatanytime,select(0)
Disabled
.
Q47: Trouble Resound After Hold Off (0-7)
DEFAULT:(0)Disabled
FireandCOsensorsarerequiredtore‐soundtroublebeeps
everyfourhoursuntilthetroubleisresolved,evenifthe
troubleisacknowledgedattheControlPanel.TheControl
Panelcanbesettodelayre‐soundingthesetypesoftrouble
beepsfor1‐7days.
NOTE: Thisfe
atureisnotallowedinUL985installations.
Thesettingmustbe(0)Disabledinthisgradeof
installation.
•Thede
faultsetting(0)Disabledallowstrouble
beepsforCOandfiresensorstore‐soundevery
four(4)hoursafterbeingacknowledged
•Todela
yre‐soundingtroublebeepsforCOandFire
sensors,select(1‐7)days
Q48: Download CSID (6 Digits)
DEFAULT:000000
Thesystemsupportsasix(6)‐digitCSIDcodethatisuse dfor
remotetelephoneprogrammingoftheControlPanel.This
codeisverifiedwhentheControlPanelconnectswiththe
downloadingsoftware.IftheCSIDcodedoesn’tmatchthe
downloadingsoftware,theControlPanelwilldenythe
connection.
•TheCS
IDcodecanbeenteredmanuallywiththis
programmingquestion.
•Ifth
isfieldisleftwiththedefault(000000),thefirst
timethedownloadingsoftwareconnectswiththe
ControlPanel,thefieldwillbefilledwiththe
software’sCSID.
Q49: Programming Mode Entry Reports
to CS (0-1)
DEFAULT:(0)Disabled
AreportcanbesenttotheCentralStationanytime
installerprogrammingmodeisenteredandexited.
•Thede
faultset ting(0)Disabledpre ventsreporting
programmingmodeentryandexit.
•Torep
ortprogrammingmodeentryandexit,select
(1)Enabled.
NOTE: Thisre
portcanonlybesentthroughthetelephone
dialer.ItisnotsupportedthroughtheGSM(Cellular)
RadioModule.
Q50: Trouble Reports to CS (0-1)
DEFAULT:(1)Enabled
TroublereportscanbesenttotheCentralStationwhenany
sensortroubleconditionoccurs.
•Thedefaultsetting(1)Enabledallowsreporting
sensortroubleconditions.
•Tonotre
portsensortroubleconditions,select(0)
Disabled.
NOTE: Thisset
tingdoesnotaffecttroublereportscaused
byControlPanelconditions,onlytroublereportscaused
bysensors.
Q51: Manual Bypass Reports to CS (0-1)
DEFAULT:(0)Disabled
ManualbypassreportscanbesenttotheCentralStation
whenanysensorhasbeenmanuallybypassedbytheuser.
•Thedefaultsetting(0)Disabledpreventssending
manualbypassreports.
•Toallowsendingmanualbypassreports,select(1)
Enabled.
Q52: AC Loss Reports to CS (0-1)
DEFAULT:(1)Enabled
ACpowerlossreportscanbesenttotheCentralStationif
theControlPanellosesACpower.
•Thede
faultsetting(1)EnabledallowsACpowerloss
reports.
•Totu
rnoffACpowerlossreports,select(0)
Disabled.
NOTE: TheACpow
erwillhavetobeabsentfromthe
ControlPanelforthetimesetbyprogrammingquestion
Q38beforetheACpowerlosstroublealert is
displayed(th
edefaultis10minutes).Ifprogramming
questionQ39isenabled,theactualACpowerloss
reportwilloccurata randomtimeofuptofourhours
aftertheACpowerlosstroublealert
isdisplayed.
NOTE: TheCon
trolPanel’sACpowericondisplaysthe
powerstatusimmediately.Ared“X”overtheicon
indicatesnoACpower.
Q53: System Low Battery Reports to CS
(0-1)
DEFAULT:(1)Enabled
LowbatteryreportscanbesenttotheCen tralStationifthe
ControlPanel’ sbatterytestslow.