Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
64Copyright©2016NortekSecurity&Control
Q: Enter Port Forward IP Address
DEFAULT:000.000.000.000
Typically,youwillsimplyacceptthedefaultIPAddressvalue
thatappears.
Q93: Enter Broadband Network Failure
Time (1-255)
DEFAULT:30Minutes
NOTE: TheGo!BridgeIPCommunicatormustbeinstalledto
usethisfunction.
Thisoptionse
tstheamountoftimerequiredfortriggering
atroubleconditionifthesystemdetectsthatthe
broadbandnetworkhaslostitsconnection.Afterthe
connectionhasbeenrestored,thetroubleconditionclears.
•Thede
faultfailuredetectionsettingis30minutes.
•Tochoosead
ifferentfailuredetectiontime,enter
thenumberofminutesbetween1‐255.
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT:(1)Enabled
NOTE: TheGo!BridgeIPCommunicatormustbeinstalledto
usethisfunction.
Thisoptionspec
ifieswhetherornottheControlPanelwill
soundanddisplayatroublealertiftheGo!BridgeIP
Communicatorlosesitsbroadbandconnection.Thetr ouble
alertcanbesilencedbytheuserattheControlPanel
(broadbandtroubleisloggedregardlessofthissetting).
Whenthebroadbandconnectionisre
stored,thetrouble
indicationsautomaticallyclear.
•Thedefaultsetting(1)EnabledallowsGo!Bridge
networkfailuretroubleindications.
•ToturnoffGo!Bridgetroubleindications,select(0)
Disabled.
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT:(1)Enabled
NOTE: TheGo!B
ridgeIPCommunicatormustbeinstalledto
usethisfunction.
IftheGo!
BridgeIPCommunicatorlosesitsbroadband
connection,theControlPanelcanreportthefault.
•Thede
faultset tingis(1)Enabledwhichturns
broadbandnetworkfailurereportingON.
•Totu
rnbroadbandnetworkfailurereportingOFF,
select(0)Disabled.
Q96: Select Send Report 3 Times on
Panel Tamper (0 to 1)
DEFAULT:(1)Enabled
NOTE: Fo
rcompliancewithUL1610,thisquestionmustbe
setto(1)disabled.
Thisopt
ionconfiguresthesystemtotransmitthree(3)
reportstotheCentralStationwhenthesystemdetectsthat
thepanel’ sbackplateisinatampercondition.
• (1)Enable
d.Thesystemtransmitsthree(3)reports
totheCentralStation.
• (0)Dis
abled.Thesystemonlytransmitsasingle
reporttotheCentralStation.
Q97: Select Sound on Normal Closing
Acknowledgement (0 to 1)
DEFAULT:(1)Enabled
Configuresthesystemtoemitasoundwhenthesystem
acknowledgesthatanopensensorhasclosed(i.e.,returned
toitsnormalstate).
• (1)Enable
d.Thesystememitsasoundonsensor
closing.
• (0)Disable
d.Nosoundisemittedonsensorclosing.
NOTE: Fo
rcompliancewithUL1610,thisquestionmustbe
setto(1)Enabled.Inaddition,Q91mustbesetto(1)
RadioModemSupplier1andQ98mustbesetto(1)
Enabled.