Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
59Copyright©2016NortekSecurity&Control
•Thedefault(1)EnabledallowsControlPanellow
batteryreports.
•ToturnoffCon
trolPanellowbatteryreports,select
(0)Disabled.
Q54: RF Low Battery Reports to CS (0-1)
DEFAULT:(1)Enabled
SensorlowbatteryreportscanbesenttotheCentral
Stationifasensorbatterytestslowandsendsalowbattery
transmissiontotheControlPanel.
•Thede
faultsettingis(1)Enabledandallowsthe
systemtosendlowbatteryreportsforsensors.
•Toturnthisfe
atureOFF,select(0)Disabled.
Q55: Opening Reports to CS (0-1)
DEFAULT:(0)Disabled
OpeningreportscanbesenttotheCentralStationeach
timethesystemisdisarmed.Theuserorkeyfobnumberis
indicatedintheopeningreport.
•Thede
faultsetting(0)Disabledpreventsopening
reports.
•Toallowopeningreports,select(1)Enabled.
Q56: Closing Reports to CS (0-1)
DEFAULT:(0)Disabled
ClosingreportscanbesenttotheCentr alStationeachtime
thesystemisarmed.Theuserorkeyfobnumberis
indicatedintheclosingreport.IfQuickArmingisenabled,
User#0isindicatedfortheclosingreport.
•Thedefaultsetting(0)Disabledpreventsclosing
reports.
•Toallo
wclosingreports,select(1)Enabled.
Q57: Alarm Restore Reports to CS (0-1)
DEFAULT:(0)Disabled
AlarmrestorereportscanbesenttotheCen tralStation
afteranalarmwheneitherthebelltimeouthasbeen
reachedorthesystemisdisarmed.Ifalarmrestoresare
enabledandswingershutdownissettotwo,arestorewill
bereportedifthesensorisclosed(normalst
ate)atbell
cutofforbecomesclosedafterbellcutoff.Ifswinger
shutdownissettoone,arestorewillonlybesentifthe
sensorisclosedatthetimeofdisarm.Restoresarenotsent
ifasensorisinswingershutdownuntilthetimeofdisarm
andthese
nsorisclosed.
•Thede
faultsetting(0)Disabledpreventsalarm
restorereports.
•Toallo
walarmrestorereports,select(1)Enabled.
Q58: Trouble Restore Reports to CS (0-1)
DEFAULT:(1)Enabled
TroublerestorereportscanbesenttotheCentralStation
whenanysensortroubleconditionclears.
•Thedef
aultsetting(1)Enabledallowsthesystemto
sendreportswhentroubleconditionsarerestored.
•Toturnthisfe
atureOFF,select(0)Disabled.
Q59: Bypass Restore Reports to CS (0-1)
DEFAULT:(0)Disabled
BypassrestorereportscanbesenttotheCentralStation
whenanysensorthatwasforcebypassedormanually
bypassedgetsrestored.
•Thede
faultset ting(0)Disabledpre ventsbypass
restorereports.
•Toallo
wbypassrestorereports,selectenabled(1)
Enabled.
Q60: AC Restore Reports to CS (0-1)
DEFAULT:(1)Enabled
ACpowerrestorereportscanbesenttotheCentralStation
whentheControlPanelregainsACpowerafteranAC
powerloss.
•Thede
faultset ting(1)EnabledallowsACpower
restorereports.
•Totu
rnoffACpowerrestorereports,select(0)
Disabled.
NOTE: TheACpo
werwillhavetoberestoredtotheControl
PanelforoneminutebeforetheACpowerlosstrouble
alert
automaticallyclears.Ifprogrammingquestion
Q39isena
bled,theactualACpowerrestorereportwill
occuratarandomtimeofuptofourhoursaftertheAC
powerlosstroublealert
hascleared.
NOTE: TheCon
trolPanel’sACpowericondisplaysthe
powerstatus.Ared“X”overtheiconindicatesnoAC
power.
Q61: System Low Battery Restore
Reports to CS (0-1)
DEFAULT:(1)Enabled
WhenalowbatteryconditionisrestoredontheContr ol
Panel,thesystemcansendarestorereporttotheCentral
Station.
•Thedef
aultsetting(1)Enabledallowsthesystemto
sendreportswhenlowbatteryconditionsare
restored.
•ToturnthisfeatureOFF,select(0)Disabled.
Q62: RF Low Battery Restore Reports to
CS (0-1)
DEFAULT:(1)Enabled
Sensorlowbatteryrestorereportscanbesenttothe
CentralStationifasensorbatteryhadtestedlowandisnow
OK.
•Thede
faultset ting(1)Enabledallowssensorlow
batteryrestorereports.
•Totu
rnoffsensorlowbatteryrestorereports,
select(0)Disabled.
Q63: Phone Fail Detect (0-1)
DEFAULT:(0)Disabled
Thesystemcanmonitorthetelephonelineconnectedto
theControlPanel.Ifthetelephonelineisshortedorcut,
theControlPanelwillindicatetelephonelinetroubleby
soundingtroublebeepsanddisplayingthenophoneicon.