Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
56Copyright©2016NortekSecurity&Control
•Tochangethetimeoutduration,enteravalued
between11to120seconds.
Q35: Abort Window Dialer Delay (0-2)
DEFAULT:(1)30Seconds
ThedefaultminimumsettingforANSI/SIACP‐01compliance
is30seconds.
Thedelaytimecanbeincreasedto45secondswithout
affectingANSI/SIACP‐01complianceonlyifthe
combinationofQ35andQ6orQ7doesnotexceedone(1)
minute.
NOTE: Thedialerde
laycanbedisabledforeachsensor
withoutaffectingANSI/SIACP‐01compliance.See"RF
SensorProgrammingQuestions"onpage42.
Thedialer(digitalcommunicator)delayscallingtheCentral
Stationtoallowtheuserenoughtimetocancelafalse
alarmbeforeitisreported.
•Thede
faultsettingis(1)30Seconds.
•Toch
angethesetting,select(0)15Secondsor(2)
45Seconds.
Q36: Burglary Bell Cutoff (0 to 4)
DEFAULT:(0)4Minutes
Whenaburglaryalarmistriggered,thebellwillsounduntil
theburglarybellcutofftimeexpires.
•Thede
faultsettingfortheburglarybellcutoffis(0)
4Minutes.
•Toch
angethecutofftime,selectanoptionbelow.
BurglaryBellCutoffTime
(0)4Minutes
(1)8Minutes
(2)12Minutes
(3)16Minutes
(4)Unlimited
NOTE: The24‐hourAuxiliaryAlarmZone(08)doesnot
followtheburglarybellcutofftimeandwillsoundthe
ControlPanel’ slocalalarmuntilaUserCodeisentered.
TheAuxiliaryAlarmZonedoesnottriggertheexternal
siren(ifused).
Q37: Fire Bell Cutoff (0-4)
DEFAULT:(0)4Minutes
Whenafirealarmistriggered,thebellsoundsuntilthefire
bellcutofftimeexpires.
•Thedefaultsetting(0)4Minutessetstheburglary
bellcutofftofour(4)minutes.
•Toch
angethefirebellcutofftime,selectanoption
below
FireBellCutoffTime
(0)4minutes
(1)8minutes
(2)12minutes
(3)16minutes
(4)Unlimited
Q38: Time to Detect AC Loss, in Minutes
(0-30)
DEFAULT:(10)10Minutes
WhenACpowerislost,theysystemdisplaysapowerloss
alertafterthespecifiedtimelength.Whenpoweris
restored,thealertisautomaticallyclearedafterone(1)
minute.
•Thede
faultdetectiontimerfordisplayingthealert
messageis(10)10Minutes.
•Tochangethedetectiontimer,enteravalue
between0to30minutes.
NOTE: Aft
ertheACpoweralert isdisplayedorclears,
theACpow
erlossreportorACpowerrestorereport
canbesenttotheCentralStationimmediately,orata
randomtime,seeQ39:RandomACLossReportTime.
NOTE: TheControlPanel’ sACPowerIconimmediately
displaysthepowerstatus.See“A
CPowerOn/OFF”on
page28.
Q39: Random AC Loss Report Time (0-1)
DEFAULT:(1)Enabled
ThisfeatureallowsthesystemtoreportACpowerlossand
ACpowerrestoreatarandomtimeofupto45minutes
aftertheeventoccurs.ThishelpstoreduceCentralStation
congestionduetoawide‐spreadpoweroutageaf fecting
manyControlPanelsatonce.TherandomACpo
werstatus
reporttimeristriggeredbasedonthetimesetbyQ38:
RandomACLossReportTime.
•Thede
faultset ting(1)Enabledturnsthisfeature
ON.
•Totu
rnthisfeatureOFF,select(0)Disabled.
Q40: CS #2 Phone Number (0-25 digits)
DEFAULT:NoDefault
ThetelephonenumberforCentralStation#2canbeupto
25digits.CentralStationtelephone#2isdialedasbackupin
casetelephone#1doesnotconnect.
•EntertheCen
tralStation#2telephonenumber.
•TapSh
ifttoaccessthepound(#)andstar(*)
symbols.ThePbuttonaddsa3‐secondpausetothe
dialing.
Q41: CS #2 Account Number (4 Digits)
DEFAULT:NoDefault
TheaccountnumberforCentralStation#2isalwaysfour
digitsandcanincludesomealphacharacters.
•Enterfo
ur(4)digitsfortheCentralStation#2
accountnumber.
•TheShiftb
uttonaccessesB,C,D,E,andF
characters.
Q42: Remote Control Phone (0-3)
DEFAULT:(3)DataandVoice
Thissettingcontrolsremotetelephoneaccesstothe
system.