Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
44Copyright©2016NortekSecurity&Control
delaytime,see"Q35:AbortWindowDialerDelay(0‐2)"on
page56.
•RFsensorscantriggerthedigitalcommunicator
immediatelyorafteradelay.Thedefaultsetting(1)
EnabledcausesdelayeddialingforthisRFsensor
number.
•Forimme
diatedialingforthisRFsensornumber,
select(0)Disabled.
NOTE: Thisse
ttingforCOandSmokeAlarmsis
automaticallysetto(0)Disabled,andthissub‐question
isskippedforthesesensortypes.
Q: Construct RF Sensor # Voice Descriptor
DEFAULT:NoDe
fault
NOTE: Fo
ralistofavailablevoicedescriptors,see"Voice
Descriptors"onpage38.
Thevo
icedescriptorsarethewordstheControlPanelwill
announceforthisRFsensorifthissensorisprogrammed
forvoiceannunciation.Uptofive(5)wordsareallowed.
1 TapInserttoplaceawordfromthevocabularyintothe
dataentryfield.
2 Tapthe←or→arr owstoscrollthroughthewords,or
entertheword’sthree(3)‐digitindexnumber.
3 TapInsertagainforthenextword.Uptofivewordsare
allowed.
4 Tomovebetweenwords,taptheFwdandBack
buttons.
5 Toremoveaword,tapDelete.
Q: Select RF Sensor # Reports (0 to 1)
DEFAULT:(1)Enable
d
RFsensorscanbeprogrammedtotriggerareporttothe
CentralStationornot.
•Thedefaultsetting(1)Enabledenablesreporting
forthisRFsensornumber.
•TopreventreportingforthisRFsensornumber,
select(0)Disabled.
Q: Select RF Sensor # Supervised (0 to 1)
DEFAULT:(1)Enabled
Whenasensorissettosupervised,theControlPanelwill
expectregulartimedsignalsfromthissensororelsea
sensorsupervisorytroublealertwilloccur.
•Thede
faultsetting(1)Enabledallowssupervision
forthisRFsensor.
•Toturnof
fsupervisionforthisRFsensor,select(0)
Disabled.
NOTE: Po
rtablesensorssuchaspanicbuttonsshouldnot
besetassupervisedifthesensorwillberemovedfrom
thepremisesattimes.
Q: Select RF Sensor# Chime (00 to 13)
DEFAULT:(0)Disabled
EachRFsensorcanbesettosounda“ding‐dong”chime
and/orsounditsvoicedescriptorwhenthesensoris
triggered.Thisstepdeterminestheinitialsettingforthe
sensor.
Theendusercanchangethechimesettingforsensors
usingChimeSetupintheUserToolbox.
•Thede
faultsetting(0)Disableddisablesthechime
forthisRFsensor.
•Ifach
imeand/orvoiceisrequiredforthisRF
sensor,chooseoneoftheotherchimeoptions:
Code SensorChime
(0) Disabled
(1)
VoiceOnly
(2) Ding‐DongwithVoice#1
(3)
Ding‐Dong#2
(4) Ding‐DongwithVoice#2
(5)
Ding‐Dong#1
(6) Ding‐Ding
(7)
Ding‐DingwithVoice
(8) Ding‐Dong#3
(9)
Ding‐DongwithVoice#3
(10) Chime#1
(11)
Chime#1withVoice#1
(12) Chime#2
(13) Chime#2withVo
ice#2
Wired Sensor Programming
TheControlPanelcanbeprogrammedwithuptotwo(2)
wiredsensors.Thewiredsensorsarehardwiredcontact
loopsconnectedtotheloopinputterminalsontheControl
Panel’ sterminalstrip.Toseewherethetwo(2)hardwired
sensorscanbewiredintotheTerminalBlock,seethe
"TerminalBlockWi
ringDiagram"onpage20.
CAUTION: WiredsensorscannotbeusedforaCOorFire
sensorloop.
IMPORTANT: NotethatWiredSensorreportsasbelow:
•WiredSensor#1=Re
portsasSensor#49
•WiredSensor#2=Re
portsasSensor#50
SeeF
igure52WiredSensorProgrammingOutlineonthe
nextpageforthestepsrequiredtoprogramwiredsensors
intotheControlPanel.Theoptionsthatcanbesetforeach
wiredsensorare:
• Q2:Wi
redSensorNumber.Select1or2.
• Q:Wi
redSensor#Type.Selectthezone.For
example,(01)Exit/Entry1,(02)Exit/Entry2,
(03)Perimeter,andsoon.See"Zone
Numbering"onpa
ge35.
• Q:Wi
redSensor#EquipmentType.Some
sensortypes(zones)willpromptyoutospecify
theequipmenttype.Othersensortypeswillnot
promptyouforanequipmenttype.
• Q:Wi
redSensor#EquipmentCode.Selectthe
four(4)‐digitequipmentcodethatcorresponds
totheappropriatesensormodel.See
"EquipmentCode
s"onpage40.
• Q:Wi
redSensor#EquipmentAge.Specify
whetherthesensorisa(0)Newor(1)Existing
sensor.
• Q:Wi
redSensor#NormalState.Choose
between(0)NotUsed,(1)Closed,(2)Open,(3)
End‐Of‐Line‐Resistor.
• Q:Wi
redSensor#DialerDelay.Specify
whethertousedelayedorinstantdigital
communicatorreportsforthesensor.Thedelay
timeissetontheDialerAbortscreen.