Q: Select RF Sensor # Equipment Type
DEFAULT:Va
riesbyRFSensorType
NOTE: Somesensortypes(zones)willrequireyoutospecify
anequipmenttypeselection,whichaffectsthesensor’s
extendedreportingcode.
Simplyentertheappropriateequipmenttypecode(see
tablebelow)ortapthe←or→arrowstoselectthe
appropriateequipmenttype.
ThetablebelowshowstheEquipmentTypesavailablefor
eachSensorType(Zone):
Q: Select RF Sensor # Equipment Code
DEFAULT:(0000)Oth
er
Selectthefour(4)digitequipmentcodethatcorresponds
totheappropriatesensormodel.See"EquipmentCodes"on
page40.
Q: Select RF Sensor # Other Equipment Code
NOTE: Thissu
bquestionisonlydisplayedif(0000)Otheris
selectedastheRFSensor#EquipmentCode.
Entertheeq
uipmentcodenumberdirectlyonthekeypad
fortheRFsensor.Enter“0”ifthenewequipmentcodeis
unknown.
Q: Enter RF Sensor # Serial Number (7 Digits)
DEFAULT:0000000
RFse
nsorserialnumberscanbemanuallyenteredor
automaticallytransmittedfromthesensortotheControl
Panel.
Fo
rmanualentry.Enterthesensornumberthat
waslog gedforthesensorbeingprogrammed.Tap
Shifttoaccessalphabeticcharacters.
Fo
rautomaticentry.TapShift,thentapLearnto
placetheControlPanelintolearningmode.Then
triggertheRFsensor.TheControlPanelwillbeep
four(4)timesandlearnthesensorsserialnumber.
Ifthese
nsorbeinglearnedisalreadyinmemory,the
ControlPanelwilldisplayasensorlearningfailurescreen
whentheprogrammingchange sarebeingsaved.
Forcertainsensorswithmorethantwoloops,thetamper
switchmustbeusedtosendasignaltotheControlPanel
duringsensorlearning.Thefir
stpressofthetamperswitch
willlearnthesensorintothepanelasLoop#1.Thesecond
pressofthetamperswitchwilllearnthesensorintothe
panelasLoop#2,andthethirdpressofthetamperswitch
willlearnthesensorintothepanelasLoop#3.Pa
use15
secondsbetweeneachpressofthetamperswitch.
TheprogrammedloopnumberofthesensorintheControl
Panelmayneedchangingtosuittheoperationofthe
device.Fordetails,seetheInstallationInstructionsincluded
withthesensor.
Q: Select RF Sensor # Equipment Age (0 to 1)
DEFAULT:(0)New
TheCon
trolPanelcanbeusedwithneworexistingRF
sensors.
•IfthisRFsensorisnewfortheinstallation,leavethe
defaultsettingof(0)New.
•Ifthi
sRFsensorisalreadyinstalled,select(1)
Existing.
NOTE: IftheRFsen
sorhasmorethanoneloopandisbeing
programmedintomultiplesensornumberstosupport
theloops,setonlyoneloopas“new”andtheother
loopsas“existing .Thiswillpreventincorrectin ventory
oftheinstalledsensors.
Q: Select RF Sensor # Loop Number (1 to 3)
DEFAULT:Va
rieswithsensormodelselected
The2GIGDoor/WindowContactsensorshavetwo(2)
inputs:aninternalmagneticcontactandanexternal
NormallyClosed(N/C)hardwiredinput.Eitherorboth
sensorinputscanbeused.
TIP: Somesensorsarecapableofthree(3)loopinputs.
NOTE: Whe
nusingboththeinternalmagneticcontactand
theexternalinput,themagnetcontactANDthe
externalcontactmustbeassignedadifferentRFsensor
number.Bothsensornumberswillsharethesame
sensorserialnumber.
•Whenprogrammingthesensortousethebuiltin
magneticcontact,settheloopnumberto(2)2.
•Whenpr
ogrammingthesensortouseitshardwired
input,settheloopnumberas(1)1.
•Whenpr
ogrammingathree(3)loopsensortouse
anadditionalinput,settheloopnumberas(3)3.
•Whenen
teringthesensornumberforthesensors
loop2or3,tapPastetorecallthelastprogrammed
sensorsserialnumber.(Thesensornumberwillbe
filledinautomaticallyifLearnisused.)
Q: Select RF Sensor # Dialer Delay (0 to 1)
DEFAULT:(1)Enabled
Ifthisfeatureisenabled,thedelaytimemustbesettoa
minimumof30secondsforANSI/SIAcompliance.Tosetthe
(02)Exit/Entry2 Y Y
(03)Perimeter YY
(04)InteriorFollower* Y Y
(05)DayZone YY
(06)24HourSi lentAlarm* Y Y
(07)24HourAudibleAlarm* YY
(08)24HourAuxi liaryAlarm* Y Y
(09)24HourFire YN
(10)InteriorwithDelay* Y Y
(14)24HourCarbonMonoxide YN
(16)24HourFireVerification Y N
(23)NoResponseType* YY
(24)SilentBurglary Y Y
SensorType(Zone) EquipmentTypes
(04)InteriorFollower (1)Motion
(2)Contact
(06)24HourSi lentAlarm (1)Contact
(11)Emergency
(07)24hourAudibleAlarm (1)Contact
(11)Emergency
(08)24HourAuxi liary (1)Contact
(6)Freeze
(8)Water
(10)Temperatu re
(11)Emergency
(10)InteriorwithDelay (1)Motion
(2)Contact
(23)NoResponseType (1)Contact
(2)Motion
SensorTypes(Zone) RF Wired

Table of Contents