Installer Programming
Copyright © 2016 Nortek Security & Control 49
Q: Enter Fob # Serial Number (7 Digits)
DEFAULT:0000000
Ke
yfobserialnumberscanbemanuallyenteredorlearned
fromthefob.
•Formanualentry,enterthefobnumberthatwaslogged
forthefobbeingprogr amme d.UsetheShiftbuttonto
accessalphacharacters.
•Forau
tomaticentry,tapShift,thentapLearn.The
ControlPanelwillwaitforafobtransmission.Trigger
thefobbeingprogrammedandtheControlPanelwill
learnthefob’ sserialnumber.
Q: Select Fob # Equipment Age (0 to 1)
DEFAULT:(0)New
TheControlPanelcanbeusedwithneworexistingkey
fobs.
•Ifthisfobisnewfortheinstallation,leavethedefault
settingof(0)New.
•Ifthi
sfobisalreadyinstalled,select(1)Existing.
Q: Select Fob # Emergency Key (0 to 4)
DEFAULT:(0)Disabled
Pressingtheandbuttonsonakeyfobatthesame
timefor5secondscantriggeranemergencyalarm.
•Thede
faultsetting(0)Disabledinactivatesthe
emergencyfunctionthefob#.
•Toena
bletheemergencyfunctionforthisfob,select
one(1)ofthefour(4)options:
•(0)Disabled
•(1)Aux
iliaryAlarm
•(2)Audi
bleAlarm
•(3)Si
lentPanic
• (4)Fire
Q: Select Fob# Key # Can Disarm (0 to 1)
DEFAULT:(1)Enabled
Asaninstaller,consulttheuserastowhethertosetthekey
fobtoallowdisarmingtheControlPanelwiththekeyfob’s
button.Iftheuserwantsthekeyfobusedasastationary
wallfob,itcanalsobesettopreventusingthekeyfobto
disarmthesystem.
•Thede
faultsetting(1)Enabledallowsthefobtodisarm
thesystem.
•Tonotallo
wthefobtodisarmthesystem,select(0)
Disabled.
Q: Construct Fob# Voice Descriptor
DEFAULT:(#)Ke
yfob
Thevoicedescriptoraretheactualthewordsthatthe
ControlPaneluseforthisfobforlowbattery
announcementsandlogentries.Uptofive(5)wordsare
allowed.
1 TapInserttoplaceawordfromthevocabularyintothe
dataentryfield.
2 Usethe←or→arrowstoscrollthroughthewords,or
entertheword’sthree(3)‐digitindexnumber.
3 TapInsertagainforthenextword.Uptofivewordsare
allowed.
4 Toremoveaword,tapDelete.
Q: Select Fob (#) Arm No Delay (0 to 1)
DEFAULT:(0)Dis
abled
KeyfobscanbesettoarmtheControlPanelwithor
withoutanentrydelay.
•Thedefaultsetting(0)Disabledsetsthisfobtoarmthe
systemwithanentrydelay.
•Tose
tthisfobtoarmthesystemwithoutanentrydelay,
select(1)Enabled.
Q: Select Fob# Key 4 Output (0-2)
DEFAULT:(0)Disabled
Pressthekeyfob’ sauxiliarybuttontotriggertheControl
Panel’ sopencollectoroutput.
Thedefaultsetting(0)Disableddeactivate sthefob’s
auxiliarybutton.
Tousethisfob’ sauxiliarybutton,selecttheoutputfunction:
•(0)Disabled
•(1)ToggleOutput
• (2)Momen
taryOutput
Wireless (RF) Keypad Programming
TheControlPanelcanbeprogrammedwithuptofour(4)
RFkeypadsorRFtouchscreenkeypads.
NOTE: RFKe
ypads1‐4reporttotheControlPanelas
sensors59‐62(foremergency,andlowbattery
reports)
RFKeypadReportingCodes
Keypad1 Reportsassensor#59
Keypad2
Reportsassensor#60
Keypad3 Reportsassensor#61
Keypad4 Reportsassens
or#62
.
•UserCo
des#1‐#8arereportedforopeningsand
closings
•UserCo
de#0isreportedforQuickArming
Thefo
llowingoptionscanbesetforeachRFkeypad:
• SelectRFKeypadNumber.Selectkeypadnumber1‐4.
• SelectRFKe
ypad#Used.Enableordisablethe
keypad.
• SelectRFKe
ypad#EquipmentCode.Selectthe
equipmentcodeforthekeypad.See"Equipment
Codes"onpa
ge40.
• SelectRFKe
ypad#OtherEquipmentCode.Ifyou
selected(0000)Other,enterthespecialequipment
code.
• SelectRFKe
ypad#Serial#.Entertheserialnumber
fromthekeypador“learn”bysendingasignal.
• SelectRFKe
ypad#EquipmentAge.Select(0)New
or(1)Existing.
• SelectRFKe
ypad#EmergencyKeys.Select(1)
Enabledor(0)Disabled.
• Co
nstructRFKeypad#VoiceDescriptor.Construct
thenameassignedforthekeypadannouncement.
See“VoiceDe
scriptors”onpage38.