52Copyright©2016NortekSecurity&Control
Control Panel Programming
Programming Questions
Q1: RF Sensor Programming
TolearnaboutRFsensorprogramming,see"Wireless(RF)
SensorProgramming"onpage41
Q2: Wired Sensor Programming
Tolearnaboutwiredsensorprogramming,see"Wired
SensorProgramming"onpage44
Q3: RF Key Fob Programming
TolearnaboutRFkeyfobprogramming,see"Wireless(RF)
KeyFobProgramming"onpage47.
Q4: RF Keypad Programming
TolearnaboutRFkeypadprogramming,see"Wireless(RF)
KeypadProgramming"onpage49
Q5: Exit Delay, in Seconds (45-120)
DEFAULT:60seconds
Thedefaultminimumsettingof60secondsisrequiredfor
ANSI/SIACP‐01compliance.Thedelaytimecanbe
increasedwithoutaffectingcompliance.
Theexitdelaytimercanbesettoavaluebetween45to
120seconds.
•Thede
faultsetting60setstheexitdelayto60
seconds.
•Tochangetheexitdelaytimer,enteravalue
between45‐120seconds.
Q6: Entry Delay 1, in Seconds (30-240)
DEFAULT:30seconds
Thedefaultminimumsettingof30secondsisrequiredfor
ANSI/SIACP‐01compliance.
NOTE: Fo
rcompliancewithANSI/SIACP‐01,thetotal
numberofminutesforthecombinationofQ6:Entry
Delay1andQ35:AbortWindowDialerDelaycannot
exceedone(1)minute.
Theti
merforEntryDelay1canbesettoavaluebetween
30to240seconds.
•Thede
faultsetting30setsthetimerto30seconds.
•Toch
angethesetting,enteravaluebetween30‐240
seconds.
Q7: Entry Delay 2, in Seconds (30-240)
DEFAULT:45seconds
Thedefaultminimumsettingof45secondsisrequiredfor
ANSI/SIACP‐01compliance.
NOTE: Fo
rcompliancewithANSI/SIACP‐01,thetotal
numberofminutesforthecombinationofQ7:andQ35:
AbortWindowDialerDelaycannotexceedone(1)
minute.
Theti
merforEntryDelay1canbesettoavaluebetween
30‐240seconds:
•Thede
faultset tingof45setsthetimerto45
seconds.
•Toch
angethetimersetting,enteravaluebetween
30‐240seconds.
Q8: Dialer (0-1)
DEFAULT:(0)Disabled
Thedialer(digitalcommunicator)canbeenabledfora
monitoredsystemordisabledforalocalalarmorwhenthe
GSM(Cellular)RadioModuleisusedexclusivelyfor
reporting.
•Thede
faultsetting(0)DisabledturnsthedialerOFF.
•Totu
rnthedialerON,select(1)Enabled.
IMPORTANT: If(0
)DisabledisselectedinQ8:Dialer,
telephonelinefailuredetectionisalsodisabled
regardlessofthesettingspecifiedinQ63:PhoneFail
Detect.
Q9: Dialing Prefix (0-4 Digits)
DEFAULT:NoDefault
SometelephonePBXsystemsrequireadialingprefixto
acquireadialtone.
•IfthetelephonesystemthattheControlPanelis
connectedtorequiresadialingprefix,enterupto
four(4)digits.
•TapSh
ifttoaccessthepound(#)andstar(*)
symbols.ThePbuttonaddsathree(3)‐second
pausetothedialing.
Q10: Call Waiting Disable Code (0-6
Digits)
DEFAULT:Nodefault
ForANSI/SIAcompliance,donotenteradisablecode.
Ifthesubscriber’stelephonelinehascallwaiting,incoming
calltonesonthelinecaninterferewithreportstothe
CentralStation.Topreventthis,thesystemcanbe
programmedtoenterthecodetodeactivatecallwaiting
beforesendingare
porttotheCentralStation:
•Ifca
llwaitingisactiveonthetelephoneline,enter
thecodetodeactivatecallwaiting.
•TapSh
ifttoaccessthepound(#)andstar(*)
symbols.ThePbuttonaddsathree(3)‐second
pausetothedialing.
NOTE: Ifth
efirstattemptfails,thiscodewillbeignoredon