Control Panel Programming
Copyright © 2016 Nortek Security & Control 61
servesasasafetyalerttothe usersotheycanenterthe
protectedpr emiseswithcaution.
•Thedefaultsetting(0)Disabledwillnotcausea
uniquesoundwhendisarmingafteranalarm.
•Tocaus
euniquesoundwhendisarmingafteran
alarm,select(1)Enabled.
Q74: Keyfob Arm/Disarm Confirmation
(0-1)
DEFAULT:(0)Disabled
Thesystemcanproduceauniquesoundwhenit’sarmedor
disarmedwithakeyfob.TheControlPanel’sspeakerwill
soundonebeepwhenarmingandtwobeepswhen
disarming.Theexternalsounder(ifinstalled)willsoundone
chirpwhenarmingandtwochirpswhendisarming(four
beepsaft eranalarmifQ73isenabled).Thisfeature
indicatestotheuserthattheirkeyfobsignalwasreceived
bytheControlPanelincaseotherarm/disarmindications
(armedLED,etc.)arenotavailableorvisibletotheuser.
•Thede
faultsetting(0)Disabledwillnotcausea
uniquesoundwhencontrolledbyakeyfob.
•Tocaus
eauniquesoundwhencontrolledbyakey
fob,select(1)Enabled.
Q75: Auto Un Bypass for Manual Bypass
(0-1)
DEFAULT:(1)Enabled
Violated(open)sensorscanbemanuallybypasse dbythe
userthroughtheUserToolboxorforcebypassedatthetime
ofarming.
Forcebypassedsensorsautomaticallyhavetheirbypasses
removedwhenthesystemisdisarmed.
Manuallybypassedsensorscanhavetheirbypass
automaticallyremovedatdisarmingorhavetheirbypasses
remaininplace.
•Thede
faultsetting(1)Enabledautomatically
removesbypassesfrommanuallybypassedsensors
whenthesystemisdisarmed.
•Toha
vemanuallybypassedsensorsremain
bypassedwhenthesystemisdisarmed,select(0)
Disabled.
Q76: Force Bypass Reports (0-1)
DEFAULT:(0)Disabled
Thesystemcanreportwhichsensorshav ebeenforce
bypassedbytheuserwhenthesystemisarmed.Forced
bypassedsensorsarealwaysrecordedintheeventlog,
regardlessofthesettingofthisprogrammingquestion.
•Thede
faultsetting(0)Disabledpreventsreporting
forcedbypassedsensors.
•Torep
ortforcedbypassedsensors,select(1)
Enabled.
Q77: Event Log (0-3)
DEFAULT:(3)AllEvents
Tocontroltheamountofeventlogentries,theeventsthat
getrecordedintothesystem’ seventlogcanbeselectedby
type.Thissettingfilterstheeventsthatpopulatetheevent
log.
•Thede
faultsetting(3)AllEventsrecordsalleventsin
theeventlog.
•Tochoosedif
ferentoptions,selectoneofthesefilters:
EventLogFilters
(0)Disabled(noeventslogged)
(1)AllEventsExceptOpen,Closing,andBypass
(2)AllEventsExceptOpenandClosing
(3)AllEv
ents
Q78: Output
DEFAULT:(11)FollowsInternalSounderAlarm
ThedefaultsettingforANSI/SIACP‐01is(11)Follows
InternalSounderAlarm.
Thesystem’sopencollectoroutputisavailableonthe
ControlPanel’ sterminalblocktoconnecttoanexternal
device.Theconditionsthatwillcausetheopencollector
outputtoactivateareprogr ammable.
• Selectoneofthesettingsbelow:
OpenCollectorOutputMode
(00)Disabled
(01)ActivatedWhenArmed
(02)ActivatedWhenDisarmed
(03)ActivatedonFTC(FailuretoCommunicate)
(04)ActivatedonSirenSupervision
(05)ActivatedonRadioFault
(06)ActivatedonBurglaryAlarm
(07)ActivatedonFireAlarm
(08)ActivatedonAnyAlarm
(09)ActivatedonAnySystemTrouble
(10)Z‐Waveactivation(Option#10notcurrently
active)
(11)FollowsInternalSounderAlarm
(12)FollowsExit/EntryBeeps
Q79: Z-Wave Feature (0-3)
DEFAULT:(3)(3)EnabledonPanel;RulesDisabled,Remote
AccessEnabled
TheZ‐Wavehomeservicesfeaturecanbeenabledor
disabledwithvariousremotecontrolaccessoptions.
•Thedefaultsetting(3)EnabledonPanel;Rules
Disabled,RemoteAccessEnableddisplaysthe
Servicesbutton,butwillshowamessagethatthe
featureiscurrentlydisabledandtheusershouldcall
theinstaller.
•TohidetheSer
vicesbutton,select(0)Disabledand
Hidden.
•Tosh
owtheServicesbuttonbutdisableitfromuse,
select(1)DisabledbutVisible.
•Tosho
wtheServicesbuttonanddisableoff‐site
remotecontrol,select(2)EnabledonPanel,Remote
AccessDisabled.
Q80: Z-Wave Switches Feature (0 to 1)
DEFAULT:(1)Enabled
DisplayoftheHomeService’sSwitchesbuttoncanbe
enabledordisabled.
NOTE: Thispr
ogrammingquestiononlyfunctionsifQ79:Z‐
WaveFeatureissetto(2)or(3).