Programming Outline
Eachsysteminstalledwillrequireprogramming.Most
installationsbeingperformedbytheprofes sionalalarm
installerforaspecificorganizationwillhavecommonvalues
setineveryControlPanelthatisreportingtotheCentral
Station.Otherprogrammingvalues,suchastheaccount
numberandsensorsetup,maybeuniqueforeach
ins
tallation.
Usethefollowingoutlinetoguideyouthroughthe
installationprocess.UnderstandingtheControlPanel s
programmingstructurewillhelptosavetimeduringeach
installation.
Atthisstagethefollowingshouldbealreadycompleted:
•Allhardwiredsensorsinstalled
•Allwi
relesssensorsinstalled
ControlPanelmounted,connected,andpowered
up
1 AttheHomescreen,tapthesystemlogointhelower
rightcorner.
Figure 48 The Home Screen
NOTE: YoucanalsotaptheInstallerToolboxbuttonfrom
thesystem’sToolbox(3of3)screen.
2 Entertheinstallercode(thedefaultinstallercodeis
1561)intheEnterYourCodetoAccesstheToolbox
screen.
3 AttheInstallerToolbox,tapSystemConfiguration.
Thenbeginthe"RFSe
nsorProgrammingQue stions"on
page42.
4 Afterprogrammingalloftherequiredsensorsintothe
ControlPanel,tapEnd,thenExit,tosavethechanges.
5 AftertheControlPanelrestarts,tapSecurity>Menu>
Tool box.
6 Whenprompted,enterthemasterusercode.The
defaultmasterusercodeis1111.
7 TaptheUserManagementbuttonandthensetupthe
usercodes.BesuretosetuptheDuressCodeasUser
#8.TapBackwhenfinished.
8 TapBrightness/Volumeandsetthelevelsforthe
installation.
9 Thevolumesettingdoesnotaffectthevolumeofalarm
sounds.
10 Tap→toviewthesecondtoolboxscreen.
11 TapBackLightTimeoutandsetthedisplaylighting
timeout.
12 TapSetDateandSetTimeandsetthecalendarand
clock.IftheGSM(Cellular)RadioModuleisinstalled,
thedateandtimesetsautomatically.
13 Pressthe buttontoreturntotheHomescreen.
Aftercompletingallsetupandprogrammingtasks,referto
theControlPanel’sUserGuideforinformationabout
operatingthesystem.Checkofftheprogrammedoptions
forthesystemintheUserGuide.
NOTE: Ins
tructtheenduseraboutpropersystem
operations,andle avetheUserGuideattheinstallation
siteforreference.
ANSI/SIA CP-01 Compliance
Severalprogrammableoptionshavethedefaultspresetto
providecompliancewiththeAmericanNationalStandards
Institutes/SecurityIndustryAssociationCP01ControlPanel
Standard.Thetablebelowdetailsthesettingsthatcomply
withANSI/SIACP01andpermanentlyprogrammedintothe
Console.TheANSI/SIACP01settingsdocumentedinthe
tablebe
lowcannotbechanged:
Programming
Questions
ANSI/SIACP 01
Setting Range
Q1>Q:SelectRFSensor#
DialerDelay(0to1)
(1)Enabled (0)Disabledor
(1)Enabled
Q2>Q:SelectWiredSen
sorDialerDelay(0to1)
(1)Enabled (0)Disabledor
(1)Enabled
Q5EnterExitDelay,in
Seconds(45120)
60Seconds 45120Seconds
Q6EnterEntryDelay1,in
seconds(45120)
30Seconds 30240Seconds
Q7EnterEntryDelay2,in
seconds(45120)
45Seconds 30240Seconds
Q10EnterCallWaiting
DisableCode(06digits)
NoDefaultCode 06Digits
Q20SelectSwingerShut
downCount(1to6)
(2)TwoTrips 16Trips
Q26SelectAutoStay
(0to1)
(1)Enabled (0)Disabledor
(1)Enabled
Q27ExitDelayRestart
(0to1)
(1)Enabled (0)Disabledor
(1)Enabled
Q31EnterCancelTime,in
Minutes(5255)
5Minutes 6254Minutes
Q32SelectCancel
Display(0to1)
(1)Enabled (0)Disabledor
(1)Enabled
Q35SelectAbortWin
dowDialerDelay(0to2)
30Seconds 15to45Seconds
Q78SelectOutput (11)Follows
InternalSounder
Alarm
NOTE:See"Q78:
Output"on
page61