Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
34Copyright©2016NortekSecurity&Control
‡IndicatesthedefaultsengforANSI/SIACP‐01compliance
*TocomplywithUL985:HouseholdFireWarningSystemUnits,thesettingforQ46:SelectTroubleDoesn’tSoundatNightmust
besetto(0)Disabled.
**TocomplywithUL1610:Central‐StationBurglar‐AlarmUnits,Q96andQ97mustbesetto(1)enabled.UL1610compliance
alsorequiresthatQ91:SelectRadioModemSupplierbesetto(1)RadioModemSupplier1.
Selectmonetary symbol(0to8) (0)$
Q84 SelectServicesRequireMasterCode (0)Disabled
Q85 SelectMasterUserAccesstoZ‐WaveToolbox(0to1) (0)Disabled
Q86 SelectDisableSirenAfterTwo‐WayAudio(0to1) (0)Disabled
Q87 SelectKeyfob/RemoteArmingModeonSystemNotReady(0
to2)
(0)Auto‐BypasswithZoneParticipationonRestore
Q88 SelectZ‐WaveSirenMode(0to1) (0)SoundforBurglaryandFire/CO
Q89 SelectAllowBacklightAlwaysOn(DemoMode) (0)Disabled
Q90 SelectEnergyFeature(0to2) (0)DisabledandHidden
Q91 SelectRadioModemSupplier VariesbySupplier**
Q92 SelectNetworkDevice(0to1) (0)none
NetworkDeviceID(Read‐Only) 0
NOTE:Onlyappearsif(1)Go!BridgeisselectedinQ92Select
NetworkDevice(0to1)
SelectConfigurationSource(0to1) (0)DHCP
If(0)DHCPisselectedinSelectConfigurationSource(0to1),
thefollowingsub‐questionsappear:
SelectPort#(1to8)
(1)Port1
NOTE:Thisoptionisautomaticallyselectedifyouchoose(0)
DHCPinthepreviousquestion.Typically,youwillskipthis
questionunlessadditionalprogrammingisrequired.
SelectUsed(0to1) (0)Disabled
NOTE:Typically,youwillskipthisquestionunlessadditional
programmingisrequired.
EnterPortValue(0‐65535) 0
NOTE:Onlyappearsif(1)EnabledisselectedinSelectUsed(0to
1)
EnterPortForwardIPAddress 000.000.000.000
NOTE:Onlyappearsif(1)EnabledisselectedinSelectUsed(0to
1).
NOTE:Typically,youwillacceptthedefaultIPaddressvaluethat
appears.
If(1)StaticisselectedinSelectConfigurationSource(0to1),
thefollowingsub‐questionsappear
EnterDeviceIPAddress
EnterGatewayIPAddress
EnterSubnetMask
Q93 EnterBroadbandNetworkFailureTime(1‐255) 30
Q94 SelectBroadbandNetworkFailureCausesTrouble(0to1) (1)Enabled
Q95 SelectBroadbandNetworkFailureReports(0to1) (1)Enabled
Q96 Selectsendreport3timesonpaneltamper(0to1) (1)Enabled**
Q97 Selectsoundonnormalclosingacknowledgment(0‐to‐1) (1)Enabled**
Q# ProgrammingQuestion/Sub‐Question DefaultSetting