Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
46Copyright©2016NortekSecurity&Control
Q: Select Wired Sensor# Equipment Type
DEFAULT:Variesbywiredsensortype
NOTE: Thisquestionisonlydisplayedwhencertainsensor
types(zones)areselected.
Thee
quipmenttypeselectionwillaffectthesensors
extendedreportingcode.
Thefollowingsensortypesrequireequipmenttype
selection:
Selecttheequipmenttypethatmatchesthesensor
equipmentusingthe←or→arrows,orenterthe
equipmenttypenumberdirectlyonthekeypad.
NOTE: ThisCon
trolPaneldoesnotprovideauxiliary
accessoryoutputpower.
Connectingah
ardwirePIRusingequipmenttype“motion”
willrequireanexternalstandalonebatterybackedup
powersupplyforthePIR.
Q: Wired Sensor # Equipment Code (0-9999)
DEFAULT:(0
)
Selectthefour(4)digitequipmentcodethatcorresponds
totheappropriatesensormodel.See"EquipmentCodes"
onpage40.
Q: Select Wired Sensor# Equipment Age (0 to 1)
DEFAULT:(0)New
TheCon
trolPanelcanbeusedwithneworexistingwired
sensors.
•Ifthiswir
edsensorisnewfortheinstallation,leave
thedefaultsettingof(0)New.
•Ifthiswir
edsensorisalreadyinstalled,select(1)
Existing.
Q: Select Wired Sensor# Normal State
DEFAULT:(0)NotUs
ed
Thetwohardwiredloopscanbewiredfornormallyopen
(N/O)ornormallyclosed(N/C)contacts,orforendofline
(EOL)resistor.
•Thede
faultsetting(0)NotUseddisablesthiswired
sensor.
•Tous
ethiswiredsensor,selectthewaytheloopis
wired:
WiredSensorNormalSt
ate
(0)No
tUsed
(1)Cl
osed
(2)Op
en
(3)En
dofLineResistor
Q: Select Wired Sensor# Dialer Delay (0 to 1)
DEFAULT:(1)Enabled
Ifthisfeatureisenabled,thedelaytimemustbesettoa
minimumof30secondsforANSI/SIAcompliance.Tosetthe
delaytime,see"Q35:AbortWindowDialerDelay(02)"on
page56.
Wiredsensorscantriggerthedigitalcommunicator
immediatelyorafteradelay.
•Thedefaultsetting(1)Enabledcausesdelayed
dialingforthiswiredsensornumber.
•Forim
mediatedialingforthiswiredsensornumber,
select(0)Disabled.
Q: Construct Wired Sensor # Voice Descriptor
DEFAULT:NoDefault
NOTE: Fo
ralistofvoicedescriptors,see"VoiceDescriptors"
onpa
ge38.
ThevoicedescriptorsarethewordstheControlPanelwill
announceforthiswiredsensorifthiswiredsensoris
programmedforvoiceannunciation.Uptofive(5)words
areallowed.
1 TapInserttoplaceawordfromthevocabularyintothe
dataentryfield.
2 Usethe←or→arrowstoscrollthroughthewords,or
entertheword’ sthree(3)digitnumber.
3 TapInsertagainforthenextword.Uptofive(5)words
areallowed.
4 Tomovebetweenwords,taptheFwdandBack
buttons.
5 Toremoveaword,tapDelete.
Q: Select Wired Sensor# Reports (0 to 1)
DEFAULT:(1)Enabled
Wiredsensorscanbeprogrammedtotriggerareporttothe
CentralStationornot.
•Thedefaultsetting(1)Enabledactivatesreportingfor
thiswiredsensornumber.
•Toprev
entreportingforthiswiredsensornumber,
select(0)Disabled.
Q: Select Wired Sensor# Chime (00 to 13)
DEFAULT:(0)Disabled
Eachwiredsensorcanbesettosounda“dingdongchime
and/orsounditsvoicedescriptorwhenthesensoris
triggered.
(04)InteriorFollower Yes Yes
(05)DayZone Yes Yes
(06)24HourSilentAlarm Yes Yes
(07)24HourAudibleAlarm Yes Yes
(08)24HourAuxiliaryAlarm Yes Yes
(09)24HourFire Yes No
(10)InteriorwithDelay Yes Yes
(14)24HourCarbonMonoxide Yes No
SensorTypes(Zones) EquipmentTypesAvailable
(04)InteriorFollower (1)=motion
(2)=contact
(06)24HourSilentAlarm (1)=contact
(11)=emergency
(07)24HourAudible
Alarm
(1)=contact(
11)=emergency
(08)24HourAuxiliary (1)=contact
(6)=freeze
(8)=water
(10)=termperature
(11)=emergency
(10)InteriorwithDelay (1)=motion
(2)=contact
(23)NoResponseType (1)=contact
(2)=motion
SensorTypes(Zones) RF
Sensors
Wired
Sensors