4-56 Section 060-INDP-410 Command and Message Guide
297-6201-502 Standard 01.02 September 2000
•LPAD
• SITDAT
• VALPARM BLOCKS
• VALPARM INVALID.
AMAHRS
AMAHRS is a Site Data command used to display or set the time interval to
verify that AMA records have been received from the Switching System. The
command requires the start and end times to perform the check and the
amount of time that can pass before an alarm is generated if no blocks are
received. Times are based on a 24 hour clock (00 to 23).
Examples of command usage
Use the following command to examine the hour boundaries currently
assigned:
>AMAHRS (cr)
The system displays the currently assigned hour boundaries as follows:
BLOCK CHECK START xx END yy HOURS, INTERVAL OF zz MINUTES
where:
xx - hour to start the block check. Range: 00-23 (default is 00).
yy - hour to stop the block check. Range:00-23 (default is 23).
zz - minutes of no blocks before alarm (default is 60).
Issue the following command to change the hour boundaries currently
assigned. The command requires the start and end times to perform the check;
checks are made on the hour. (If a data block has not been received between
the hour boundaries, an alarm is generated.)
>AMAHRS xx yy zz (cr)
The system displays the following message after changing the hour
boundaries:
BLOCK CHECK START xx END yy HOURS, INTERVAL OF zz MINUTES
Note 11: For full-time block checks, enter 00 for Start, and 23 for Stop.
Note 12: If no block checks are required, enter 00 for Start and 00 for
Stop and 00 for Interval.