4-70 Section 060-INDP-410 Command and Message Guide
297-6201-502 Standard 01.02 September 2000
where:
side- TEC/DSI port ID: 1 (TEC/DSI PCA in slot 13) or 2 (TEC/DSI
PCA in slot 12)
port- decimal number that specifies a port. Range: 0-255.
The system displays the data at the specified port address.
TECMAINT IOWRITE
TECMAINT IOWRITE writes data to a specified TEC/DSI port address.
Example of command usage
Use the following command to write data to a specified TEC/DSI port
address:
>TECMAINT IOWRITE side port data (cr)
where:
side- TEC/DSI port ID: 1 (TEC/DSI PCA in slot 13) or 2 (TEC/DSI
PCA in slot 12)
port- decimal number that specifies a port. Range: 0-255.
data- data to be written to a TEC/DSI port. Range: 00-FF.
TECMAINT MEMWRITE
The TECMAINT MEMWRITE command writes data to TEC/DSI memory
starting at a specified address.
Example of command usage
Use the following command to write data to a specific TEC/DSI memory
address.
>TECMAINT MEMWRITE side address datalist (cr)
where:
CAUTION
Improper use of this command may result in an attempt to
write data to a non-existent memory location, or, cause
erroneous data to be written to a memory location that is
already in use by other data. Do not use this command
without first contacting technical assistance personnel to
determine that it is proper to do so.

Table of Contents

Other manuals for Nortel DMS-10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel DMS-10 Series and is the answer not in the manual?

Nortel DMS-10 Series Specifications

General IconGeneral
BrandNortel
ModelDMS-10 Series
CategoryTelephone System
LanguageEnglish

Related product manuals