3 ON-SITE CONDITIONS
3.1 Ground Conditions
Level, solid oor covering, preferably with spike-friendly overlay.
Maximum permitted incline: 15 %
3.2 Room Ventilation
In accordance with OSHA (North America), VDE (Europe) and local codes, the battery rooms
should be designed such that natural ventilation is adequate (see OSHA 1926.441 or VDE 510).
3.3 Water Connections
Ice making water on the left hand side of the ice resurfacer.
Wash water on the right hand side of the ice resurfacer.
The intake can be controlled with a solenoid valve. The solenoid valve is controlled by the
ice resurfacer. Valve size is 1”.
3.4 Water Quality
Clean water with low total grains of hardness.
Ice making water temperature as hot as local codes will allow.
Wash water: cold only.