The Ultimate Ice Resurfacer 42
The lling process can be interrupted or stopped at any time by turning the selector switch to
the centre position.
The control panel function can be used even when the ignition key is turned o, provided the
battery connector is plugged in.
Connection of the Ice Making Water Line
First connect the water line to the water ll pipe on the side of the dash and then connect
the solenoid valve to the supply socket on the panel. Turn the ll level selector switch to the
desired setting (full or half-full). When the preselected water level is reached, the solenoid
valve automatically turns o.
Always be sure to insert the ll hose into the ice resurfacer rst.
Disconnection of the Ice Making Water Line
Proceed in the following order to disconnect the water hose from the ice resurfacer:
1. Turn the selector switch to the neutral position.
2. Pull the plug out of the socket.
3. Disconnect the hose from the ice resurfacer.
This procedure prevents the solenoid valve from opening before the water hose is connected
to the ice resurfacer when the next ll takes place, thus preventing water from pouring out in
an uncontrolled manner.
When the ½ or full mark is reached, the solenoid valve shuts o the supply of water.