The Ultimate Ice Resurfacer 51
Watering The Batteries:
A battery watering cart is supplied with each ice resurfacer.
1. Connect the hose coupling to the respective battery trays.
2. Turn on the pump in the cart.
3. The batteries are automatically lled with distilled water until the oat valve at the
individual battery cells stop the lling process. The water ow indicator in the hose
will stop spinning when the tray is full. This process must be repeated on both battery
trays.
The optimal charging cycle for a maximum life expectancy of the battery is as follows:
1. Discharge until the battery is as close to 0% on the accumeter charge indicator as
possible.
2. Recharge uninterrupted for 7-8 hours.
3. If at all possible do not attempt to charge the battery between resurfacings
(opportunity charge).
Opportunity charging, although sometimes may be necessary should be avoided as it decreases
the overall life of the battery.