3-68
Operation
Origin compensation value
Advance angle compensation value 1
(angle data)
Use the mode selection switch to change to SET mode.
Backlash compensation value
Advance angle compensation value 1 (speed data)
Advance angle compensation value 2
(angle data)
Advance angle compensation value 2 (speed data)
Advance angle compensation value 3
Baud rate
• If the advance angle compensation value (Function No. b, Parameters 3 to 5) is displayed, the present
settings will be displayed in the SPEED/ON and POSITION/OFF displays and the first digit (rightmost
digit) will be flashing. (The SPEED/ON display will be blank for advance angle compensation value 3.)
• Use the Forward, Up, and Down Keys to change the data. (For advance angle compensation values 1
and 2, use the ON/OFF Switching Key to switch between speed and angle data.)
• Press the Set Key and the data will remain lit for approximately one second, the setting will be con-
firmed, and the display will resume flashing.
• If the data is inappropriate and the Set Key is pressed, all displays will flash twice and then return to the
settings before the data was edited. Re-input the correct data.
Operation Chapter 3