Function level 2
3-78
Operation
Backlash compensation enable/disable Output hold
Present value
output setting
Use the mode selection switch to change to SET mode.
Various compensation values
enable/disable setting
• When output hold (Function No. H, Parameter No. 3) is displayed, the present settings will flash in the
SPEED/ON display.
• Use the Up and Down Keys to set the data.
• Press the Set Key. The data will remain lit for approximately one second, the settings will be confirmed,
and then the data will resume flashing again.
3-6-10 Present Value Output Function
H Function
The present value output uses the cam output signal and output signals that are sent to the M7E or M7F
Display Units.
H Related Parameter (SET Mode)
D Present Value Output Setting
Function
No.
H (h)
Parameter
No.
4 Setting range 0 to 4
• Use this parameter to set the present value output function.
• The settings are as follows:
0: No present value output function (factory setting)
1: 4-digit present angle output (no units)
2: 4-digit speed output (no units)
3: 3-digit automatically switching present angle/speed output (with units)
4: 4-digit automatically switching present angle/speed output (with units)
For automatically switching data output, the present angle data will be output when the speed is less
than 4 r/min and the speed data will be output when the speed is 4 r/min or greater.
• Use settings 1 to 4 for M7E Display Units and 1 or 2 for M7F Display Units.
• The present value output signals are the same as cam output signals. When this function is used,
therefore, some cam outputs can no longer be used. (Different cam outputs are used for 3F88L-160
and 3F88L-162 Cam Positioners.)
Note 1. This parameter is enabled when the power is turned OFF and then ON again.