Function level 2
3-69
Press the Clear Key to return the data to the factory settings. If the Clear Key is pressed, the three
digits of data will start flashing. Press the Set Key while the data is flashing and the display will change
to “– – –” and the factory settings will be restored. If the Clear Key is pressed again while the data is
flashing, the data will not be initialized and the display will return to the edited status.
D Advance Angle Compensation Enable/Disable
Function
No.
H (h)
Parameter
No.
2 Setting range 0, 1
Set to “1” to enable advance angle compensation. (0: Advance angle compensation disabled; 1: Ad-
vance angle compensation enabled.)
The factory setting is “0.”
Note This parameter is enabled when the power is turned OFF and then turned ON again.
Operation
Backlash compensation enable/disable Advance angle compensation enable/disable
Present value
output setting
Use the mode selection switch to change to SET mode.
Various compensation value
enable/disable settings
If the advance angle compensation enable/disable function (Function No. H, Parameter No. 2) is dis-
played, the present settings will flash in the SPEED/ON display.
Use the Up and Down Keys to set the data.
Press the Set Key and the data will stop flashing for approximately one second, the setting will be con-
firmed, and the display will resume flashing.
3-6-7 Cam Protect
H Functions
The cam protect function protects cams and banks from accidental changes or deletion of cam ON/
OFF data.
Operations are limited in the following ways when data is cam protected.
Protected cam data cannot be changed or deleted.
Banks containing protected cam data cannot be deleted.
The PCLR operation (clear all cam programs) cannot be performed.
If any of these operations are attempted, an E-22 (cam protect input prohibited) error will be dis-
played. (The program will not be changed or deleted.)