3-49
3-6-3 Parameter Explanation and Operation
H Explanation
In this section, individual parameters will be explained in the following format.
Parameter name Function level setting
Function
No.
• (Function explanation)
Note (Additional information)
D Origin Compensation Value
b (b)
1Parameter
No.
Setting range 0 to 359 (0 to 719) (see note 1)
Function level 2
w Parameter Name
Parameter names such as “origin compensation value” and “backlash compensation value” will ap-
pear here.
w Function Level Setting
The function level at which this parameter can be set will appear here.
In the above example, this parameter can be set at function level 2 (all functions) only.
w Function No.
The function number of this parameter will appear here.
The 7-segment indicator display will appear in parentheses after function numbers that appear as
letters (rather than numerals).
w Parameter No.
The parameter number for this parameter will appear here.
w Setting Range
The setting range for this parameter will appear here.
w Function Explanation
The functions and factory settings for this parameter will be explained here.
w Additional Information
Additional information for items with “See note” as well as information on restrictions or cautions
pertaining to the use of that function will appear here.
H Items to be Checked before Setting Parameters
The functions and parameter setting for 3F88L-160/162 Cam Positioners will be explained in the next
section. Before proceeding, be sure to check that the following two settings have been made.
• Set the function level (Function No. U) to “2” (function level 2).
• Set the resolution selection (Function No. A) to the resolution to be used.
Once these settings have been made, turn OFF the Cam Positioner and then turn it ON again.
If additional parameters are set without the power being turned OFF and then ON again, the function
levels and resolution selections will not be enabled and the parameters, therefore, will not be set proper-
ly.
Operation Chapter 3