3-6-13 Copy Function (Data Transfer)
H Function
The copy function receives and transmits data (cam programs and parameters) between two Cam
Positioners.
By setting one Cam Positioner as the Master and one as the Slave, data can be read, written, and
verified.
Cam Positioners are connected via communications ports by RS-232C cables.
H Connecting RS-232C Cables
D Connecting Cam Positioners
RS-232C cables are connected via the Cam Positioner communications ports.
Communications
port
RS-232C cable
Communications
port
3F88L-160/162
Cam Positioner
3F88L-160/162
Cam Positioner
D Communications Port Pin Arrangement
Pin No. Symbol Signal name Pin No. Symbol Signal name
1 NC --- 6 NC ---
2 RD Receive data 7 RS Send request
3 SD Send data 8 CS Send
enabled
4 NC --- 9 NC ---
5 SG Signal
ground
Shell FG Frame
ground
D RS-232C Cable Assembly
An RS-232C cross cable is used for communications between Cam Positioners (9-pin D-sub, socket –
socket type)
9-pin 9-pin
Shield
Shell
Shell